![background image](http://html1.mh-extra.com/html/nibe/f2040-12/f2040-12_installer-manual_1686263062.webp)
Working range, compressor operation - cooling
F2040-6 , -8 , -12 , -16
65
58
55
40
60
50
45
35
25
30
20
15
43
40
30
25
20
10
0
-10
-20
-30
50
Utomhustemperatur (°C)
35
30
15
25
20
12
7
10
5
0
45
40
43
35
30
25
20
15
10
50
Vattentemperatur (°C)
Vattentemperatur (°C)
Utomhustemperatur (°C)
Water temperature °C
Outdoor air temperature °C
Framledning
Returledning
Framledning
Returledning
Supply temperature
Return temp
F2040
Chapter 11 |
Technical data
62
Summary of Contents for F2040-12
Page 1: ...Installer manual LEK LEK LEK UN F2040 6 8 12 16 Air water heat pump IHB EN 1746 6 231844 ...
Page 2: ......
Page 47: ...Connection to board AA23 BP4 BT15 BT12 BT3 AA23 S3 47 Chapter 8 Disturbances in comfort F2040 ...
Page 74: ...F2040 Chapter 11 Technical data 74 ...
Page 77: ...F2040 12 77 Chapter 11 Technical data F2040 ...