Working range, compressor operation - heating
F2040-6 , -8 , -12 , -16
65
58
55
40
60
50
45
35
25
30
20
15
43
40
30
25
20
10
0
-10
-20
-30
50
Utomhustemperatur (°C)
35
30
15
25
20
12
7
10
5
0
45
40
43
35
30
25
20
15
10
50
Vattentemperatur (°C)
Vattentemperatur (°C)
Utomhustemperatur (°C)
Water temperature °C
Outdoor air temperature °C
Framledning
Returledning
Framledning
Returledning
Supply temperature
Return temp
During shorter time it is allowed to have lower working temperatures on the water side, e.g. during start up.
61
Chapter 11 |
Technical data
F2040
Summary of Contents for F2040-12