General
■
The heat pump must not be connected without the
permission of the electricity supplier and must be
connected under the supervision of a qualified electri-
cian.
■
If a miniature circuit-breaker is used, this must have
motor characteristic “C” (compressor operation). For
MCB size, see “Technical specifications”.
■
F2040 does not include an omnipolar circuit breaker
on the incoming power supply. The heat pump’s supply
cable (W1) must therefore be connected to a circuit
breaker with a breaking gap of at least 3 mm. If the
building is equipped with a residual current device,
the heat pump should be equipped with a separate
one. The residual current device should have a nominal
tripping current of no more than 30 mA. Incoming
supply must be 230 V 50Hz via electrical distribution
units with fuses.
■
If an insulation test is to be carried out in the building,
disconnect the heat pump.
■
Communication cable (W2) is inserted from the rear
side through UB2.
■
Connect communication cable (W2) from terminal
block (AA23-X4) to the indoor module.
NOTE
Electrical installation and any servicing must
be carried out under the supervision of a qual-
ified electrician. Disconnect the current with
the circuit breaker before carrying out any ser-
vicing. Electrical installation and wiring must
be carried out in accordance with the national
stipulations in force.
NOTE
Check the connections, main voltage and phase
voltage before the machine is started, to pre-
vent damage to the air/water heat pump
electronics.
NOTE
The live external control must be taken into
consideration when connecting.
NOTE
If the supply cable is damaged, only NIBE, its
service representative or similar authorised
person may replace it to prevent any danger
and damage.
F2040-6
LEK
AA23
AA23-X100
AA23-S3
AA23-X4
AA23-F3
AA23-X1
RF2
UN
PWB1
PWB2
PWB3
TB
F2040
Chapter 5 |
Electrical connections
26
5 Electrical connections
Summary of Contents for F2040-12
Page 1: ...Installer manual LEK LEK LEK UN F2040 6 8 12 16 Air water heat pump IHB EN 1746 6 231844 ...
Page 2: ......
Page 47: ...Connection to board AA23 BP4 BT15 BT12 BT3 AA23 S3 47 Chapter 8 Disturbances in comfort F2040 ...
Page 74: ...F2040 Chapter 11 Technical data 74 ...
Page 77: ...F2040 12 77 Chapter 11 Technical data F2040 ...