F2040-16
LEK
Främre el
Bakre el
LEK
LEK
Secure the communication
cable (W2) here using two
cable ties.
External heating cable KVR 10 (Accessory)
F2040 is equipped with a plinth for external heating
cable EB14 not supplied). The connection is fused with
250 mA (F3 on the communication board AA23). If an-
other cable is to be used, the fuse must be replaced with
a suitable one (see table).
NOTE
Self regulating heating cables must not be
connected.
NIBE Part no.
Fuse
Fuse (F3)
Total
power
(W)
Length
(m)
718085
T100mA/250V
15
1
518900*
T250mA/250V
45
3
718086
T500mA/250V
90
6
* Fitted at the factory.
Connect external heating cable (EB14) to terminal block
X1:4–6 according to following image:
5
6
4
2
3
1
External
F2040
X1
EB14
External heat cable
AA23
F3
NOTE
The pipe must be able to withstand the heat
from the heating cable.
To ensure this function the accessory KVR 10
should be used.
33
Chapter 5 |
Electrical connections
F2040