Operating mode "Add. heat only"
In the event of malfunctions that cause a low indoor tem-
perature, you can normally activate "Add. heat only" in
HBS 16, which means that heating only occurs with the
immersion heater.
Activate the mode by holding in the operating mode
button
for 7 seconds.
Note that this is only a temporary solution, as heating with
the immersion heater does not make any savings.
Deactivate the function by pressing the "Operating mode"
button for 7 seconds once again.
Emergency mode
Emergency mode is activated by setting the switch to ”
”. It is used when the control system and thereby op-
erating mode "Add. heat only" do not function as they
should. Emergency mode is activated by setting switch
(SF1) to ”
”.
The following applies in emergency mode:
႑
The front panel is not lit and the control computer in
HBS 16 is not connected.
႑
AMS 10-16 is off and only the circulation pump HBS 16
and the immersion heater in HE 30, HEV 300, HEV 500
are active.
႑
An electrical step of 4 kW is connected. The immersion
heater is controlled by a separate thermostat (BT30).
႑
The automatic heating control system is not operational,
so manual shunt operation is required. Call installer.
15
NIBE™ SPLIT
For Home Owners
Dealing with comfort disruption
Summary of Contents for AMS 10-16
Page 2: ...HE 30 LEK LEK LEK LEK LEK HEV 300 LEK HEV 500 LEK LEK AMS 10 16 LEK HBS 16 ...
Page 70: ...Electrical circuit diagram HBS 16 NIBE SPLIT 68 Miscellaneous Electrical circuit diagram ...
Page 71: ...69 NIBE SPLIT Miscellaneous Electrical circuit diagram ...
Page 72: ...NIBE SPLIT 70 Miscellaneous Electrical circuit diagram ...
Page 73: ...71 NIBE SPLIT Miscellaneous Electrical circuit diagram ...
Page 74: ...NIBE SPLIT 72 Miscellaneous Electrical circuit diagram ...
Page 75: ...73 NIBE SPLIT Miscellaneous Electrical circuit diagram ...
Page 76: ...AMS 10 16 NIBE SPLIT 74 Miscellaneous Electrical circuit diagram ...
Page 100: ...NIBE SPLIT 98 ...
Page 101: ...99 NIBE SPLIT ...
Page 102: ...NIBE SPLIT 100 ...
Page 103: ......