Figure 2. cRIO-905x Front Panel
2
3
4
6
8
9
1
7
5
1. LEDs
2. USB 2.0 Type-C Device Port with Console Out
3. USB 3.1 Type-C Host
4. PFI 0
5. RESET Button
6. Power Connector
7. Grounding Screw
8. MicroSD Card Removable Storage
9. RJ-45 Gigabit Ethernet Ports
Note
The cRIO-905
x
may have 1 Ethernet port or 2 Ethernet ports depending on
the model.
Connecting the Controller to Ground
You must connect the cRIO-905
x
grounding terminal to the grounding electrode system of the
facility.
What to Use
•
Ring lug
•
Wire, 1.3 mm
2
(16 AWG) or larger
•
Screwdriver, Phillips #2
What to Do
Complete the following steps to ground the cRIO-905
x
.
1.
Attach the ring lug to the wire.
2.
Remove the grounding screw from the grounding terminal on the cRIO-905
x
.
cRIO-905x Getting Started Guide
|