19
Example: You can set your range from 15:00 to
20:00. If the filtration clock is set from 07:00
to 22:00, the chlorine production of your
STERILOR Duo will only operate from 15:00 to
20:00 without affecting the filtration.
However, it is better to carry out a low level of
treatment but over a longer duration rather
than intense production over a very short
time.
Take care to validate the adjustment made
by opening and closing the cover to prevent
any over or under-chlorination due to an
operating error. In fact, the input value
becomes the reference value.
4.7 SERVOCONTROL Mode
4.7.1 Slow Mode – Cover servocontrol
Displaying and operating the Slow Mode
STERILOR Duo is equipped with the
Slow Mode option, for modulating the
production of chlorine according to the open
or closed position of the cover.
For this, the cover limit switch contact
must be connected to the connection
intended for this purpose and using the cable
supplied.
(
Important: this contact must
absolutely be a dry contact - not connected
to the power supply
)
The cover connection is located to the left of the
box.
On the screen, the Cover area characterises the
open or closed position of the cover
Open cover yellow LED screen:
When the cover is open, chlorine is produced
based on the setting that you defined in normal
production mode.
Red LED screen Cover closed:
When you close the cover, STERILOR Duo
automatically reduces the production value by
half. You can also adjust this value manually.
Manual setting of the percentage of production
with the cover in closed position
Production is regulated as in normal
mode by keeping the P key pressed down and
using the +/- keys.
Take care to validate the adjustment made by
opening and closing the cover to prevent any
over or under-chlorination due to an operating
error. In fact, the input value becomes the
reference value.
4.7.2 Chlorine Measurement Servocontrol
Displaying and operating the Chlorine Regulator
servocontrol
STERILOR Duo is equipped with the
chlorine Regulator option, which stops the
production when the STERILOR analyser-
regulator (e.g. Stéredox) contact recognises
that the chlorine measurement threshold has
been exceeded.
Held down
Held down
Held down
Held down