21
5 INSTALLATION OF THE pH REGULATION PART
5.1 Location
STERILOR Duo
The electronic box must be installed in the
technical room protected from sunlight, bad
weather and close to the electrolysis cell (2.5
m cable).
The controls of the box (switch, electrode
connection and fuse holder) must remain
accessible.
For correct priming of the injection pump, the
height between the product suction strainer
and the pump of the box must not exceed
1.50 metres.
5.2 pH sensor assembly
Or optional bypass pH sensor assembly kit
Max. height: 1.50 m
Saddle tee with pH
sensor with its adapter
Filtration
box
Earth socket towards
separate earth
electrode
Liquid pH
injection
pH
electrode
Towards booster
compressor heating,
Towards drains
Swimming
pool
inflow
Swimming
pool
backflow
¾ salt electrolysis cell
installed
Measuring chamber with pH
electrode
Dry contact
Coupling to a chlorine
measurement,
e.g. STEREDOX
Dry contact: Slow mode or
Cover mode
control
GENERAL PRESENTATION OF THE INSTALLATION OF A SWIMMING POOL TECHNICAL ROOM
Measuring chamber
with pH electrode