ALERTS
LIST
NXAMPMK2 USER MANUAL
PAGE 45 / 70
POWER SUPPLY1 OVERTEMPERATURE
Abnormal
temperature
has been detected by the
temperature sensor on
the heat sink of the power
supply.
FAN starts rotation at max
speed
A. Environmental
temperature is too high
B. Unexpectedly
overloaded
Check the air flow
POWER SUPPLY2 OVERTEMPERATURE
– ONLY 4X4
Abnormal
temperature
has been detected by the
temperature sensor on
the heat sink of the power
supply.
FAN starts rotation at max
speed
A. Environmental
temperature is too high
B. Unexpectedly
overloaded
Check the air flow
AMPLIFIER MUTING OUTPUT
The output is muted to
protect the amplifier
All channel Mute.
A. Environmental
temperature is too high
B. Unexpectedly
overloaded
This alert is triggered only
if the alert condition cannot
be removed by other
protections such as limiter,
mute and fan rotation.
FAN1 ERROR
Error detected on Fan 1
Number of malfunctioned
fans:
1 of 3: Display alert
message on GUI.
2 or more of 3:
Automatically shut down
and reboot. After reboot,
Error Screen displayed
until the causes are
removed.
This alert is triggered when
CPU cannot sense the
fan's actual rotation speed,
which implies:
A. FAN might malfunction.
B. FAN rotation sensing
circuit might malfunction.
Call service center
FAN2 ERROR
Error detected on Fan 2
Number of malfunctioned
fans:
1 of 3: Display alert
message on GUI.
2 or more of 3:
Automatically shut down
and reboot. After reboot,
Error Screen displayed
until the causes are
removed.
This alert is triggered when
CPU cannot sense the fan's
actual rotation speed, which
implies:
A. FAN might malfunction.
B. FAN rotation sensing
circuit might malfunction.
Call service center
Summary of Contents for NXAMP4x1mk2
Page 68: ...USER NOTES PAGE 68 70 NXAMPMK2 USER MANUAL USER NOTES ...
Page 69: ......