Scene
Recall
Scene i
Scene
X
Recalls a scene. It is possible to assign this
function to several pins to be able to switch
between several scenes.
Channel
mute
Mute i
Channel
X
X
X
Mutes or unmutes one channel.
OUTPUT PINS CONFIGURATION
In Custom Mode, to configure the output pins (monitoring functions), press GPOutputs. Outputs pins are
numbered from GPO 1 to GPO 8. To configure an output pin, follow the same steps as above for the input
pins.
Name
Short Name
Options
Possible States
Description
Low
High
Imp.
Power amp
starting
status
Started
X
Power amp is started.
Scene
recall status
Scene i
Scene
X
X
Scene parameter 1 is recalled for the chosen
polarity.
Analog
inputs mute
status
An. In Mute
X
X
Analog inputs are mute (does not apply to
Analog Fallback Mode ON and input channels
muted).
Digital
inputs mute
status
Di. In Mute
X
X
Digital inputs are mute
Stand-by
status
Stand-by
X
X
Stand-by mode is ON.
Running
status
for
CP4SW
Running
High when stand-by mode is OFF. Blinking
when stand-by.
Max volume
status
Max Volume
High when maximum volume is reached on at
least one channel. Blinking when an increase
command is received.
Min volume
status
Min Volume
High when minimum volume is reached on at
least one channel. Blinking when a decrease
command is received.
Mute status
All Mute
X
X
All channels are muted (overmute).
Attenuation
status
All Atten.
X
X
All channels are attenuated.