OPTIONS
NXAMPMK2 USER MANUAL
PAGE 31 / 70
OPTIONS
The Option menu, accessible from the Header Menu, gives access to a large range of settings for many of
the NXAMPmk2 parameters. This section describes each available sub-menu.
ALERTS
On this screen are displayed all the data stored about Errors, Alarms, Warnings (see APPENDIX).
•
Amp protects
•
Fans stopped
•
Limiting output
•
Muting output
•
Channel Mains error / Power Supply / DC out / Overtemp / High Load / Low load
•
Card Overclocking / Not ready / Audio err
•
Analog fallback
LOAD MONITORING
The NXAMPmk2 Load Monitoring is an impedance monitoring function, measuring in real-time the
impedance on the amplifier output channel. This allows to report (through its GPIO port or network) whether
the speakers are correctly connected to the amplifier and ready to use. This function can be enabled and
configured on every channel.
This is particularly useful for safety installations where the status of connected speakers should always be
known, and any fault in the audio chain should be reported.