ems100
Product Manual, Issue 4
www.nexo.com
Page 57
5.3.28 Buzzer enable (b0)
Display
Description
Enables or disables a warning buzzer for alarm conditions. Door open alarms always
sound the warning buzzer regardless of this parameter setting.
Considerations
Following alarm conditions trigger the buzzer:
Refrigeration system failure (rSF) Sensor failure (PF1, PF2). Ht alarms
Door alarms sound the buzzer as standard.
Range
00 (disabled) or 01 (enabled)
Global default
01 (enabled)
5.3.29 Saving temperature disable (PEr)
Display
Description
Disables the saving mode temperatures so that the controller maintains the
Ready mode temperatures at all times.
Disabling the Saving mode temperatures does not affect the light functionality.
Considerations
None
Range
00 (off) or 01 (on)
Global default
00 (off)
5.3.30 Learning period (LP)
Display
Description
Defines whether the controller uses a 1-day or a 7-day learning period.
Considerations
None
Range
00 (1 day) or 01 (7 days)
Global default
00 (1 day)
All manuals and user guides at all-guides.com