5.3.5 Delay to saving (dS)
Display
Description
Defines the delay in switching to the Saving mode from Ready mode.
The delay starts at the end of the last active 30 minute period of the Ready mode.
Considerations
Set in multiples of 30 minutes.
Range
0 to 120 minutes (in multiples of 30 minutes)
Global default
00 (no delay)
5.3.6 Lights delay (Ld)
Display
Description
Defines the delay to switch off the cooler lights after the controller switches to the
Saving mode.
Considerations
Set in multiples of 30.
Should only take affect once Delay to saving (dS) has completed.
Range
0 to 120 minutes
Global default
00 (no delay)
5.3.7 Saving restart period (Sr)
Display
Description
Cooler runs at the ready mode temperatures for the duration of this period to ensure
that the product is at the ready mode temperatures prior to retail outlet opening time.
Considerations
•
Set and verified by OEMs through the test protocol to ensure that product
temperatures are within specification when outlets open.
• Set in multiples of 30 minutes.
Range
0 to 240 minutes (in multiples of 30 minutes)
Global default
120 minutes