5.3.23 High voltage (HI)
Display
Description
Defines the maximum voltage allowed before switching off the compressor. The high
voltage (HI) values are 10% of the actual line in voltages (see table below).
Considerations
• Must not be used with an external voltage stabiliser
• Must only be used with an Elstat supplied transformer
Global default
0 (disabled)
110-120V line
220-240V line
voltage
HI
voltage
HI
Disabled
0
220
22
120
12
230
23
130
13
240
24
140
14
250
25
260
26
270
27
Note: Voltage measurement is accurate to typically ± 10%
Caution
High voltage protection is not calibrated and actual performance can be influenced by
several factors. Therefore, total protection cannot be guaranteed.