Operation of the handle.
A stove mitten and long ash pan / air control tool are supplied with this stove for your use
when operating the stove, if the mitten supplied is of the incorrect size for the user, then it is
recommended that the user sources a CE approved stove mitten or glove to the correct size
before lighting and operating this stove.
To Open the door:
Turn the handle anti clockwise.
To close the door:
Turn the handle clockwise ensuring the door is fully closed.
Handle adjustment to ensure the stove door is fully sealed when closed
:
Only adjust
the handle when the stove is
not in use
and the stove is
cold
. With the door open
the handle can be adjusted as the handle spindle and the hole in the door are both threaded.
Rotate the handle clockwise to untighten the door closure or turn anti clockwise to tighten the
door closure.
The stove handle may need to be adjusted occasionally as the door seal over time can
compress and wear, or whenever the door seal is replaced. This adjustment is recommended to
be undertaken by an approved stove engineer.
Operation of the primary and secondary air controls
The primary and secondary air controls are located below the stove door, to operate pull to
open thus increasing the air flow or pushing to close thus reducing the air flow.
Always use
a
suitable stove mitten or glove and use the ash pan / operating tool to adjust the air setting
controls.
Very Important:
Warning:
The firebox door shall be kept
closed
except during ignition, refueling and
removal of residue material.
It is highly recommended
providing the ash pan is not full of residue material that the ash
pan is emptied when the fire
is not in use
and the stove, and all residue and components are
cold.
The stove door should
never
be opened when the stove is being fired vigorously and only
opened when the fire requires lighting, when the fuel is low and needs to be re fueled and
removal of residue material via the ash pan, at all other times the stove door
must be closed
.
4.3.1 Use with wood:
See figure 4
It is recommended
always
to use approved and suitable stove tongs for loading and refueling
the stove with wood to avoid any part of your arms and hands entering or touching the stove.
Use the stove mitten to hold the tongs.
Always use
the long ash pan / operating tool and stove mitten to operate the air controls
.
Summary of Contents for Windermere 5 SE
Page 9: ...9 Fig 1 1 Main grate positioning Fig 1 2 Top steel baffle positioning...
Page 12: ...12 Fig 1 6 Banking bar positioning Fig 1 7 Ash pan positioning...
Page 52: ...52 4 9 Part Identification Windermere 5 SE...
Page 54: ...54 5 0 Declaration of Performance Energy label Product Fiche 5 1 Declaration of Performance...
Page 55: ...55 5 2 Energy Label...