42
4.4 Maintenance
(
By a professional registered, and approved, stove installer)
Refer to:
Current National laws, Building Regulations & any Rules in Force. Also refer to:
(Approved Document J England & Wales).
The stove should be
regularly serviced
(At least once every year) by an approved and
competent stove installer such as Hetas registered (England & Wales) or equivalent for other
Nations to ensure continued safe and efficient operation.
Keep the stove instructional manual safe and readily available so the installer / maintenance
engineer as detailed above has a reference to the maintenance and service checks as sections
4.4, 4.4.1 & 4.4.2
Maintenance & service checks
only
to be carried out when the stove is
not in use and cold,
the only
exception
to this is when it is required to test the stove for safe and efficient operation
when the stove is alight where adequate precautions must be taken.
Always
comply with all
Health and Safety Regulations
whist servicing and maintaining this
stove.
Ensure the correct PPE is used
for each operation that is being undertaken, for example,
suitable protective masks whilst cleaning the stove and re painting stove, suitable hand
protection gloves to protect from any sharp edges, broken glass and any residue materials,
suitable eye protection goggles to protect against sharp objects, broken glass and any dust or
particles. Suitable body and clothes protection. If vacuuming ashes and any residue material,
ensure the vacuum cleaner is suitable and approved for stove use and is equipped with the
correct HEPA filters.
Check to ensure the chimney and flue system is in sound condition and working correctly and
safely.
Check that the chimney has been swept and inspected by a suitably qualified and registered
chimney sweep to ensure that the chimney / flue is clean and free from any obstructions and to
check that the chimney / flue is in sound and safe serviceable condition, also to check the
chimney / flue is suitable for the stove being serviced.
Remove all non-bolted stove parts within the stove. Clean all parts and check for wear and
damage. Any parts that are worn or damaged to be replaced with authorized replacements.
Note: Vermiculite parts can become brittle with use so take care whilst removing and re fitting.
It is recommended that these parts should be changed at least annually of before if required.
Whist all the non-bolted parts are removed from the inside of the stove clean all remaining
internal stove parts, check all other internal stove parts for wear and damage and replace with
authorized parts if required. Remove both top baffles for cleaning and checking, replace with
authorised parts if required.
Replace the ceramic glass panel fibre rope seal, ensure the rope seal is the same type and size
as the original.
Replace the fibre rope seal to the door, ensure the rope seal is the same type and size as the
original.
Check all external parts of the stove for wear and damage if found replace with authorised
parts.
Check the stove collar and stove pipe for damage and wear and ensure any joints are sealed
correctly. Rectify with authorized parts if any fault is found.
Summary of Contents for Windermere 5 SE
Page 9: ...9 Fig 1 1 Main grate positioning Fig 1 2 Top steel baffle positioning...
Page 12: ...12 Fig 1 6 Banking bar positioning Fig 1 7 Ash pan positioning...
Page 52: ...52 4 9 Part Identification Windermere 5 SE...
Page 54: ...54 5 0 Declaration of Performance Energy label Product Fiche 5 1 Declaration of Performance...
Page 55: ...55 5 2 Energy Label...