6
Emission data wood.
PM mg/m3
@ 13% 02: 11
OGC mg/m3
@ 13% 02: 79
CO emission mg/m3
@ 13% 02: 1250
NoX mg/m3
@ 13% 02: 109
Emission data Maxibrite smokeless fuel
PM mg/m3
@ 13% 02: 13
OGC mg/m3
@ 13% 02: 29
CO emission mg/m3
@ 13% 02: 875
NoX mg/m3
@ 13% 02: 114
2.0 Installation introduction
2.1 Unpacking the stove
After removing the outer packaging, remove the stove from the wooden pallet and place it on a
suitable floor. The cardboard packaging can be placed underneath to prevent marring. Note: There
are 4 lower bolts supplied for fitment into holes in the base of each leg, these are adjustable to
allow level adjustment of the stove to uneven surfaces.
We recommend that two people perform the assembly and installation procedure.
2.2 Installing this stove
The stove and chimney installations
MUST
comply with all current National and Local Building
Regulations and any Rules in Force including current issues of British Standard BS 8303 code of
practice for installation of domestic heating and cooking appliances approved solid mineral fuel
and British Standards BS EN 15287-1 design, installation and commissioning of chimneys; your
approved dealer or your local building control officer can advise regarding this. Ultimately, it is
you and your installer who is responsible to ensure that the installation complies with all relevant
regulations and any rules in force.
For installations within England and Wales also refer to Document J that gives guidance on
complying with the Building Regulations.
2.2.1 Tertiary air control.
The Tertiary air intake and control is a standard part for the Easedale 5 SE and as such is
assembled to the stove at manufacture. The tertiary air intake has been designed to leave the lower
air intake slider 3mm open when the tertiary air control is in the closed position. When burning
logs or approved smokeless fuel the tertiary air control was set at the closed position.
Summary of Contents for Easedale 5 SE
Page 8: ...8 Figure 1 2 Bottom brick positioning Fig 1 3 Grate positioning...
Page 9: ...9 Fig 1 4 Lower baffle positioning Fig 1 5 Side view of stove showing lower baffle position...
Page 11: ...11 Fig 1 8 Ash pan positioning...
Page 49: ...49 3 7 Expolded view with part identification for Easedale 5 SE...
Page 50: ...50 3 8 Declaration Of Performance...
Page 51: ...51 3 9 Energy label The Energy label shown uses wood as the preferred fuel...