The secondary air wash control above the top of door should be fully closed when the stove
body is hot.
The tertiary air control to be closed.
Lighting
Important:
Ensure the area around the stove is clear of all obstacles so as not to be a trip hazard and
allowing a totally unobstructed space whilst lighting, re-fueling, adjusting the air controls and
at all other times.
1)
Push the tertiary air control to the closed position.
2)
Slide the top secondary air control to fully open. Open fully the primary air control.
3)
Open the stove door and lay a reasonable quantity of firelighters or rolled up newspapers
on the grate, if necessary, also use dry kindling wood. Place a small quantity of approved
smokeless fuel on top.
4)
Light the newspaper or firelighters using a long taper and close the stove door.
5)
When the fire is beginning to burn briskly, slowly open the stove door and add further fuel,
close the stove door.
6)
When the stove body is hot, close the top secondary air control completely to the end of its
travel.
The burning rate can now be adjusted by the primary air control, to achieve the nominal
heat output of 5kw, the maximum fuel load of 0.75kg of approved smokeless fuel should
burn for 1 hour before needing to be refueled then the stove will be operating at the
nominal heat output of about 5kw.
Re-fuelling. See figure 4
1) When the fuel being burnt is low and requires to be refueled open the primary air control.
2) Open the glass stove door and add fuel. (To load fuel, the door should be opened slowly,
avoiding a sudden rush of intake air, so that emissions do not escape into the room.). Close the
door.
3) Leave the primary air control fully open for a few minutes to allow the initial volatiles in the
fuel to burn.
4) Adjust the primary air control to achieve the nominal heat output of 5kw, the maximum fuel
load of 0.75kg of approved smokeless fuel should burn for 1 hour before needing to be refueled.
Fuel overloading.
Never overload the firebox. The maximum amount of fuel specified in this manual should
not be exceeded, overloading can be dangerous, cause excess smoke and damage the stove.
Ensure that all fuel is placed so as not to touch and obstruct the glass and door when
closed, all
fuel to be loaded behind the banking bar, ensuring that all fuel does not project
passed the
banking bar.
Never leave the appliance unattended for long periods and always ensure that the newly
charged approved smokeless fuel is burning well before leaving the room.
Do not refuel when a large amount of flames and fuel are in the firebox as this could cause
smoke or flames to spill into the room. Only re fuel when the fuel and fire is low
Close the stove door immediately after re-fueling.
Summary of Contents for Easedale 5 SE
Page 8: ...8 Figure 1 2 Bottom brick positioning Fig 1 3 Grate positioning...
Page 9: ...9 Fig 1 4 Lower baffle positioning Fig 1 5 Side view of stove showing lower baffle position...
Page 11: ...11 Fig 1 8 Ash pan positioning...
Page 49: ...49 3 7 Expolded view with part identification for Easedale 5 SE...
Page 50: ...50 3 8 Declaration Of Performance...
Page 51: ...51 3 9 Energy label The Energy label shown uses wood as the preferred fuel...