![Newman Easedale 5 SE Installation & User'S Instructions Download Page 38](http://html1.mh-extra.com/html/newman/easedale-5-se/easedale-5-se_installation-and-users-instructions_1679779038.webp)
38
equipped with the correct HEPA filters.
The stove should be regularly serviced (At least once every year) by an approved and competent
stove installer such as Hetas registered (England & Wales) or equivalent for other nations to
ensure continued safe and efficient operation. Some simple procedures are given below under
sections 3.3.3 and 3.3.4 which the user can also adopt.
Service checks:
Only when the stove is not in operation and the stove & chimney is
cold.
Check to ensure the chimney and flue system is in sound condition and working correctly and
safely.
Check that the chimney has been swept and inspected by a suitably qualified and registered
chimney sweep to ensure that the chimney / flue is clean and free from any obstructions and to
check that the chimney / flue is in sound and safe serviceable condition, also to check the
chimney / flue is suitable for the stove being serviced.
Remove all non-bolted stove parts within the stove. Clean all parts and check for wear and
damage. Any parts that are worn or damaged to be replaced with authorized replacements.
Note: Vermiculite parts can become brittle with use so take care whilst removing and re fitting.
It is recommended that these parts should be changed at least annually of before if required.
Whist all the non-bolted parts are removed from the inside of the stove clean all remaining
internal stove parts, check all other internal stove parts for wear and damage and replace with
authorized parts if required. The top baffle can be unbolted so it can be removed for cleaning
and checking.
Replace the glass panel fibre rope seal, ensure the rope seal is the same type and size as the
original.
Replace the fibre rope seal to the door, ensure the rope seal is the same type and size as the
original.
Check the Carbon Monoxide alarm to ensure it is operating correctly.
Check that any combustible materials are a safe distance from the stove.
Check room ventilation air supply to ensure the safe operation of the stove.
Air Supply:
It is
essential to check any air supply ventilator in the room is fully clear and open.
Check for correct operation of all air controls.
Check the correct operation and adjustment of the door handle.
Clean the glass panel as section 3.3.3
Clean or repaint the external black painted surfaces of the stove as section 3.3.4
All parts to be re installed to the stove into their correct positions.
To carry out correct and safe operation tests of the stove as listed in section 2.96
Commissioning and handover. Also refresh the user on the safe operation of this stove.
Summary of Contents for Easedale 5 SE
Page 8: ...8 Figure 1 2 Bottom brick positioning Fig 1 3 Grate positioning...
Page 9: ...9 Fig 1 4 Lower baffle positioning Fig 1 5 Side view of stove showing lower baffle position...
Page 11: ...11 Fig 1 8 Ash pan positioning...
Page 49: ...49 3 7 Expolded view with part identification for Easedale 5 SE...
Page 50: ...50 3 8 Declaration Of Performance...
Page 51: ...51 3 9 Energy label The Energy label shown uses wood as the preferred fuel...