self-tapping screw or bolt nut and washers do not obstruct the stove collar flue way and ensure the
screws or bolts and locating holes are airtight.
The chimney or flue way that the stove pipe is connected must be of at least 125mm internal
diameter. (ii) rectangular or square flues having the same internal cross-sectional area and a
minimum dimension of 100mm for straight flues or 125mm for flues with bends or offsets. Refer
to current Building Regulations, any Rules in Force including BS 8303 and BS EN 15287-1
*(This must be confirmed with HETAS or Local Authority Building Control and all current
National laws, Building regulations and any Rules in Force).
Fig 3.
The left picture shows the flue collar and fixings if using the stove top flue exit.
The right picture shows the flue exit blanking plate and fixings if not using the stove top flue
exit, in this case you would have opted to use the rear flue exit of which the flue collar and
fixings would be installed.
Figure 3A
Showing the configuration if using the top flue exit.
The stove flue collar is installed to the top of the stove and the flue exit blanking plate is installed
to the rear of stove flue exit.
Summary of Contents for Easedale 5 SE
Page 8: ...8 Figure 1 2 Bottom brick positioning Fig 1 3 Grate positioning...
Page 9: ...9 Fig 1 4 Lower baffle positioning Fig 1 5 Side view of stove showing lower baffle position...
Page 11: ...11 Fig 1 8 Ash pan positioning...
Page 49: ...49 3 7 Expolded view with part identification for Easedale 5 SE...
Page 50: ...50 3 8 Declaration Of Performance...
Page 51: ...51 3 9 Energy label The Energy label shown uses wood as the preferred fuel...