background image

 

Start Setup

 

 

 

Exit Setup

                                                                                                                                                                                         

19

 

In  the  sensing  reading  mode,  the  scanner  can  set  the  reading  time.  in  the  unit  of  1  second,  the  parameter  rangs  from 

0-15sec, 0 means non-stop. The scanner also can set the time interval in the interval reading mode (stable sensing reading 

time). Interval time is in the unit of 500ms, which can be set in 15 levels (from 01-15). 

 

Set the Barcode Reading Time

 

 

 

Set the Scanning Time Intervals

 

 

The customer can select the sensitity according to the environmrnt, in order to increase the reading efficiency.   

 

High Sensitivity

 

 

 

Low Sensitivity

 

 

 

Medium Sensitivity

 

 

 

Custom Sensitivity

 

 

Sensitivity Setup in the Sense Mode 

It can be set in 16 levels from 0 to F, the samller the value, the higher the sensibility. 

Example: 

The steps of set the sensibility to level 5. 

1.  Read the 

“Start Setup”barcode. 

2.  Read 

the “Custom Sensibility” barcode. 

3.  Read the numeric 

“5” barcode. 

4.  Read the 

“Exit Setup” barcode. 

Continuous Reading Mode 

The device going to continuous reading without triggered. After successful barcode reading, the scanner will become 

standby, and keep doing same loop. 

Summary of Contents for NLS-HR15XX-30

Page 1: ...NLS HR15Series NLS HR15XX 30 Corded 1D Barcode Scanner User Guide ...

Page 2: ...al product Regarding to the product modification and update FuJianNewland Auto ID Tech Co Ltd reserves the right to make changes to any software or product to improve reliability function or design at any time without notice This manual contains all the information is protected by copyright Any Company and individuals should not in any way or reason for any form of extract copy sell all or part of...

Page 3: ...n Cable 6 Power on Power off Sleep Reboot 7 Power on 7 Power off 7 Sleep 7 Reboot 7 Reading Window Maintenance 7 Reading Depth of Field 8 Specification 9 Overview 10 Left View 10 Front View 10 Vertical View 10 Barcode Reading 11 Chapter 2 General Configuration 12 Introduction 12 Setting Barcode 12 Setting Command 12 Format of Setup Barcode 12 Use the Setting Barcodes 13 Use the Setup Command 13 Se...

Page 4: ...d 23 Introduction 23 Chapter 4 Communication Setup 24 Serial Port Setup 24 Baud Rate Setup 24 Check Setup 25 Stop Bit 25 Flow Control Setup 25 Data Bit 25 USB Function Setup 26 USB Virtual Keyboard Function 26 USB Virtual Serial Port Function 27 Keyboard Function Setup 28 Keyboard Layout 28 Set the Delay between Characters 28 Character Conversion 29 Chapter 5 Data Format Setup 30 Introduction 30 P...

Page 5: ...Value 38 AIM 128 Allow to Read AIM 128 or not 38 Code ID Setup 39 Set the Barcode Reading Length 39 EAN 8 40 Restore Default Value 40 Allow to Read EAN 8 or not 40 Code ID Setup 40 Set Whether or not to Read 2 Digit Extracode 40 Set Whether or not to Read 5 Digit Extracode 41 Set Whether or not to Send the Check Digit 41 EAN 13 42 Restore Default Value 42 Allow to Read EAN 13 or not 42 Set Whether...

Page 6: ... CodeID Setup 49 Set Whether or not to Transimit the Check Digit 49 Set Whether or not to Transmit the System Digit 0 49 Set Whether or not to Read 2 Digit Extracode 50 Set Whether or not to Read 5 Digit Extracode 50 Interleaved 2 of 5 51 Restore Default Value 51 Allow to Read Interleaved 2 of 5 or not 51 Code ID Setup 51 Set Whether or not to Transmit the Check Character 51 Set the Barcode Readin...

Page 7: ... CodeID Setup 61 Check Setup 62 Set the Barcode Reading Length 62 Standard 25 63 Restore the Default Value 63 Allow to Read Standard 25 or not 63 CodeID Setup 63 Check Setup 64 Set the Barcode Reading Length 64 Code 39 65 Restore the Default Value 65 Allow to Read Code 39 or not 65 CodeID Setup 65 Check Setup 66 Set whether to Send the start and stop character or not 66 Set the Reading Range of AS...

Page 8: ...Setup 75 Set the Barcode Reading Length 76 MSI Plessey 76 Restore the Default Value 76 Allow to Read MSI Plessey or not 77 CodeID Setup 77 Check Setup 77 Set the Barcode Reading Length 78 GS1 Databar 79 Restore the Default Value 79 Allow to Read GS1 Databar or not 79 CodeID Setup 79 PDF417 79 Restore the Default Value 79 Allow to Read PDF417 or not 80 CodeID Setup 80 MicroPDF417 80 Restore the Def...

Page 9: ...Save and Abort the Setup 94 ...

Page 10: ......

Page 11: ...on Setup Serial port parameter setup and USB function setup have been introduced in this chapter Chapter5 Data Format Introduces how to use the prefix and suffix to satisfy the customers requirement to obtaining more barcode data Chapter6 Barcode Parameter Setup In this chapter all the barcodes which HR15 scanner supports have been listed and the revelant parameter setup barcodes have been provide...

Page 12: ...15 corded scanner is included in this chapter with several pictures if your have a HR15 corded scanner in your hand please compare the real scanner with this manual which will help you to understand this manulbetter This chapter is applicable to normal users maintenance staff and software developer Unpacking Open the package and take out HR15 corded scanner and its accessories Please check the com...

Page 13: ...ition 1 of HR15 connector factory default PIN Definition Type Description 1 NC Null 2 NC Null 3 VCC P Power 5V 4 TXD O RS232 Output 5 RXD I RS232 Input 6 CTS I Stream Control Signal 7 RTS O 8 GND P Ground 9 D I O USB Signal 10 D I O ...

Page 14: ...5V 4 TXD O RS232 Output 5 RXD I RS232 Input 6 CLK2 I O PC Clock Signal 7 DATA2 I O PC Keyboard Signal 8 GND P Ground 9 D I O USB Signal 10 D I O Communication Port HR15 must be connected with a host for further operation such as PC POS or any intelligent terminal with USB RS232 or PS 2 interface USB USB interface on the host RS232 RS232 interface on the host ...

Page 15: ...5 corded scanner with host through USB cable 1 Plug the RJ45 connector into HR15 scanner 2 Plug the USB connector into Host Using RS232 Cable Connecting the HR15 corded scanner with host through RS232 cable 1 Plug the RJ45 connector into HR15 scanner 2 Plug the RS232 connector into Host 3 Connect the RS232 cable with power adapter ...

Page 16: ...apter 4 If necessary please connect the normal keyboard with PS 2 cable Remove the Communication Cable Follow the figure instruction use a paper clip or spicule to push into the disassemble hole to remove the cable from HR15 1 Please remove the power adapter first if use RS232 or PS 2 cable connects with 2 Insert and push the spicule into the disassemble hole 3 Pull out the cable and remove the sp...

Page 17: ... scanning is carried out in a period of time Reboot If the HR15 no response or abnormal please pull out the cable from Host PC then plug again to reboot the HR15 Reading Window Maintenance The scanning window should keep clean Avoid hard and rough objects to clean the reading window that will easy to cause the damage or scratch Use soft brush to remove the stain on the scanning window Please use t...

Page 18: ...8 Reading Depth of Field ...

Page 19: ... mm Dimensions of Cradle L x W x H 195 x 82 5 x 47 mm Weight of Corded Scanner 152 g Reminder Beep and LED indicator Power Adaptor Output DC5V 1 5A Input AC 100 240V 50 60Hz Environmental Operation Temperature 10 C to 50 C 14 F to 122 F Storage Temperature 20 C to 60 C 4 F to 140 F Humidity 5 95 non condensing Static Discharge 12 kV Air discharge 8 kV Direct discharge Drop 1 5 m drop to concrete S...

Page 20: ...0 Overview Left View The picture below is the left view of HR15 scanner Front View The picture below is the front view of HR15 scanner Vertical View The picture below is the vertical view of HR15 scanner ...

Page 21: ...ery high success ratio in certain distance which can be regarded as the optimal scanning distance order to find the optimal scanning distance When the scanner respond with a beep and the red illuminating line goes off it means the barcode reading is successful and the scanner will send the data to the host Note For the same batch of barcode the scanner will keep a very high success ratio in certai...

Page 22: ... to setting the barcode engine In the following chapters in addition to setting code we will introduce the setting of the command string Notice All the setting command will keep in barcode engine except a few temporary setting commands will disappear after reboot or power off Format of Setup Barcode This is the sample of setup barcode The setup barcode label is consisted of three parts 1 The barco...

Page 23: ...ting barcodes The data code in the appendix includes all the necessary numerical values In the default mode the scanner will not send the current settingcommand to the host in case of a special need the customer can set the scanner tosend the setting cpmmand to the host The function of setup will not be affected whether the setting command are sending or not But the setup of Send the setting comma...

Page 24: ...25430B Description The Firmware v1 7 5 Decoder v1 00 023 C6 FD25430B among in and is the query results And FD25430B is the data string CRC32 checksum value By definition if the feedback may contain the invisible character it will be shown as hexadecimal characters every two characters indicate one character value Such as AAAA100423C5008001FF400001FF400001FF400001FF400001FF4000000040800000408000004...

Page 25: ... Start Setup Exit Setup 15 SetupProcess Flow ...

Page 26: ...e to Factory Default Work Mode Selection Power Off Reboot Test mode Note 1 Wake up the scanner please pressing trigger 2 The work mode is a temporarily setting the device will restore to the previous mode after reboot or power off Reading Mode Manual Scanning Mode Default setting the scanner will begin to read the barcode after the trigger is pressed it will stop after successful reading or if the...

Page 27: ...again In the default mode it is not allowed to repeatedly read the same barcode Auto Scanning Mode In the auto scanning mode the unit of barcode scanning time is 1 second The parameter range from 0 to15 second 0 means continue scan It is also can set to allowed to scanning barcode repeatedly Set Barcode Reading Time Not allowed to read the same barcoderepeatedly Allowed to read the same barcoderep...

Page 28: ...is value can be change The length of reading time is fixed on 100 ms Intermittent Reading Set the Scanning Time Interval Note The time interval is counted in units of 500ms which can be set in 15 levels from 01 15 For example Example The steps of set the time interval to 5000ms 1 Read the Start Setup barcode 2 Read the Set the Scanning Time Interval barcode 3 Read the numeric 1 and 0 barcode 4 Rea...

Page 29: ...the sensitity according to the environmrnt in order to increase the reading efficiency High Sensitivity Low Sensitivity Medium Sensitivity Custom Sensitivity Sensitivity Setup in the Sense Mode It can be set in 16 levels from 0 to F the samller the value the higher the sensibility Example The steps of set the sensibility to level 5 1 Read the Start Setup barcode 2 Read the Custom Sensibility barco...

Page 30: ... reading time and the time intervals Set the Barcode Reading Time Set the Scanning Time Intervals In the extended sense reading mode the barcode reading time takes 2sec as the unit the parameter range is 0 30sec 0 means non stop The time interval takes 200ms as the unit the parameter ranges from 0 to 300ms Command Triggered Reading Mode After setup to begin triggered scanning by sending the stop c...

Page 31: ...er to Describe Unsuccessful Reading Security Level Setup This value indicates the number of times to decode before correct reading of the confirmation code the higher value indicated the wrong decoded rate is lower and slower decode speed on the contrary faster the decode speed Set Security Level to 1 Set Security Level to 3 Set Security Level to 2 Set Security Level to 4 Decoding Sound Setup Turn...

Page 32: ...Laud High Frequency Median Low Frequency Weak High Frequency Weak 150ms Sound Length Intermediate Frequency Laud 100ms Sound Length Intermediate Frequency Median 50ms Sound Length Other Setup Activate Abort Temporary Mute Active Temporary Mute Exit Temporary Mute ...

Page 33: ... Introduction In order to inquire the HR15 cradle information can feed back to the host by reading the setup barcode Inquire all the Information Inquire the Release Date Inquire the Firmware Information Inquire the Product Name Inquire the Serial Number ...

Page 34: ...tup Baud Rate Setup When the scanner connects with host by serial port both sides should set the same parameters in order to guarantee the smooth communication the baud reta transmission speed of communication is necessary 9600 1200 2400 4800 14400 19200 38400 57600 115200 ...

Page 35: ...t Setup Exit Setup 25 Check Setup No Check Even Check Odd Check Stop Bit 1 Stop Bit 2 Stop bits Flow Control Setup No Flow Control CTS Flow Control RTS Flow Control RTS_CTS Flow Control Data Bit 8 Data Bits ...

Page 36: ...ck 2 Stop Bit 8 Data Bits no Check 1 Stop Bit 8 Data Bits Even Check 2 Stop Bit 8 Data Bits Even Check 1 Stop Bit 8 Data Bits Odd Check 2 Stop Bit 8 Data Bits Odd Check 1 Stop Bit 7 Data Bits Even Check 2 Stop Bit 7 Data Bits 7 Data Bits Odd Check 2 Stop Bit 7 Data Bits Even Check 1 Stop Bit 7 Data Bits Odd Check 2 Stop Bit ...

Page 37: ... Start Setup Exit Setup 27 USB Virtual Serial Port Function USB Virtual Serial Port Function ...

Page 38: ...h Italy 2 nd Japanese 8 th Norway 3 rd Danish 9 th Spanish 4 th Finland 10 th Turkey Q 5 th France 11st Britain 6 th Turkey F Set the Delay between Characters The range of the delay time between characters is from 0 to 75 ms it takes 5ms as one level totally 15 levels The default value is 0ms ...

Page 39: ... Start Setup Exit Setup 29 Delay Setup Between Characters Character Conversion No Conversion All Lowercase Letter All Capital Letter Case the Opposite ...

Page 40: ...barcode will increase the barcode length and make it unflexible thus this method does not deserve recommendation Then we thought about to add something before or after the barcode data which can be added or shielded according to the requirement The things we add are the prefix and suffix of barcode data This method can help to meet the requirement and it is not necessary to change the barcode Note...

Page 41: ...profix is finished by reading any barcode the scanner will add custom prefix character string CODE before the data AIM ID Prefix AIM is abbreviation of Automatic Identification Manufacturers AIMID defines the identifier for every kind of standard barcode see the appendix After decoding the scanner can add the identifier before the barcode data which can be regarded as AIMID prefix It is not Allow ...

Page 42: ...arcode with data 123 the scanner adds AB after 123 and the host will receive AB123 It is not Allow to Add Custom Suffix Allow to Add Custom Suffix Define the Custom suffix Read the Set the Custom suffix first and then read the hexadecimal value of every byte of the suffix character string which will be set according to priority Set the Custom suffix For example Set the custome suffix to AGE the he...

Page 43: ...ifferences between end mark suffix and custom suffix It is not Allow to Add End Mark Suffix Allow to Add End Mark Suffix Define the End Mark Suffix Read the Define the End Mark Suffix first and then read the hexadecimal value of every byte of the suffix character string which will be set according to priority Set the end mark suffix to 0x0D and make it can be sent Set the End Mark Suffix Set the e...

Page 44: ... Start Setup 34 Exit Setup After setup of it is allowed to add end mark suffix is finished by reading any barcode the scanner will add newline after the final data ...

Page 45: ...ng the barcode the parameter setup of Code 128 will be restored to the factory default state Restore the Default Setup Value of Code 128 Allow to Read Code 128 or not Allow to Read Code 128 Prohibit Reading Code 128 Note the scanner will become unable to read Code 128 by reading the setup barcode Prohibit Reading Code 128 thus if the scanner is unable to read the Code128 please try to read the set...

Page 46: ...the Maximum Length Limit to adjust the maximum length limit Set the Minimum Length Limit Set the Maximum Length Limit Note the maximum length limit of any 1D barcode must not exceed 255 if the maximum length is shorter than the minimum length then the scanner is only able to read the barcodes with the minimum length and the the maximum length if the maximum length equals to the minimum length then...

Page 47: ...up function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID CodeID Setup Example Set the CodeID of UCC EAN 128 to p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode ...

Page 48: ...acters 1 Read the Start Setup barcode 2 Read the barcode of Set the Minimum Length Limit 3 Read the numeric barcode 8 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the barcode of Set the Maximum Length Limit 6 Read the numeric barcode 1 7 Read the numeric barcode 2 8 Read the Save barcode see the appendix numeric barcode 9 Read the Exit Setup barc...

Page 49: ...t be read or transmitted Read the barcode of Set the Minimum Length Limit to adjust the minimum length limit Read the barcode of Set the Maximum Length Limit to adjust the maximum length limit Set the Maximum Length Limi Set the Minimum Length Limit Note the maximum length limit of any 1D barcode must not exceed 255 if the maximum length is shorter than the minimum length then the scanner is only ...

Page 50: ...r is unable to read the EAN 8 please try to read the setuo barcode allow to read EAN 8 Code ID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID CodeID Setup Example Set the CodeID of EAN 8 to p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read ...

Page 51: ... part of the new barcode which combines the normal barcode and extended barcode can not be read By setting The Barcode Must Include 2 Digit Extracode the scanner is only able to read the 2 digits extracode Set Whether or not to Send the Check Digit The barcode data of EAN 8 is fixed in 8 characters the 8 th digit is the check digit for checking the correctness of the 8 characters Do not read the 2...

Page 52: ...Whether or not to Send the Check Digit The data of EAN 13 barcode is fixed 13 digit the 13rd bit is the check bit which is used in checking the correctness of alll the 13 digit Send the Check Digit Send the Check Digit Code IDSetup To activate the setup function by reading CodeID Setup then read and save the hexadcimal value inaccordance with the character which will be set to the CodeID CodeID Se...

Page 53: ...code Must Include 5 Digit Extracode Note By setting Allow to Read 2 Digit Extracode the scanner can read the new barcode consisted of normal barcode and extracode and the normal barcode without extracode By setting Do not read the 2 Digit Extracode the scanner can only read the normal barcode part of the new barcode the additional part of the new barcode which combines the normal barcode and exten...

Page 54: ...SN or not Allow to Read ISSN Prohibit Reading ISSN CodeID Setup To activate the setup function by reading CodeID setup then read and save the hexadcimal value inaccordance with the character which will be set to the CodeID CodeID Setup Example Set the CodeID of ISSN to p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode Do not Extend the Barcode into 13 Di...

Page 55: ...bit Reading ISBN Note the scanner will become unable to read ISBN by reading the setup barcode Prohibit Reading ISBN thus if the scanner is unable to read the ISBN please try to read the setuo barcode allow to read ISBN ISBN Data Length Setup Adopt 13 Characters Adopt 10 Characters CodeIDSetup To activate the setup function by reading CodeID setup then read and save the hexadcimal value inaccordan...

Page 56: ...UPC E Note the scanner will become unable to read UPC E by reading the setup barcode Prohibit Reading UPC E thus if the scanner is unable to read the UPC E please try to read the setuo barcode allow to read UPC E Set Whether or not to Send the Check Digit The data of UPC E barcode is fixed 8 digit the 8st bit is the check bit which is used in checking the correctness of alll the 8 digit Send the C...

Page 57: ...d 2 Digit Extracode The Barcode Must Include 2 Digit Extracode Set Whether or not to Read 5 Digit Extracode 5 Digit extended code means to add 5 Digit numeric barcode behind the normal barcode Do not read the 5 Digit Extracode Allow to read the 5 Digit Extracode The Barcode Must Include 5 Digit Extracode Note By setting Allow to Read 2 Digit Extracode the scanner can read the new barcode consisted...

Page 58: ...ata bit Extend the Barcode Infornmation into UPC A means extend the data bit and leave the barcode type unchanged Extend the Barcode Infornmation and Type into UPC A means extend the barcode type and data bit Do not Extend the Barcode Infornmation Extend the Barcode Infornmation into UPC A Extend the Barcode Infornmation and Type into UPC A UPC A Restore Default Value By reading the barcode the pa...

Page 59: ...acter which will be set to the CodeID CodeID Setup Example Set the CodeID of UPC Ato p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the Exit Setup barcode Set Whether or not to Transimit the Check Digit The barcode data of UP...

Page 60: ...behind the normal barcode Do not read the 5 Digit Extracode Allow to Read 5 Digit Extracode The Barcode Must Include 5 Digit Extracode Note By setting Allow to Read 2 Digit Extracode the scanner can read the new barcode consisted of normal barcode and extracode and the normal barcode without extracode By setting Do not read the 2 Digit Extracode the scanner can only read the normal barcode part of...

Page 61: ...Code ID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID CodeID Setup Example Set the CodeID ofInterleaved2 of 5 to p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appendix numeric barcode 4 Read the Save bar...

Page 62: ...f Interleaved2 of 5 to 4 characters and do not send check digit in such circumstances the scanner is not able to read the Interleaved2 of 5 with 4 characters Set the Barcode Reading Length The scanner is only able to read the Interleaved2 of 5 with tramsmission content length falls in the limited range the range is consisted of the maximum value and minimum value in units of character the maximum ...

Page 63: ... not Transmit the Check Digit Allow to Read ITF 6 and Transmit the Check Digit Note if the setup of ITF 6 confilits with the setup of Interleaved2 of 5 for example reading ITF 6 is allowed but reading Interleaved2 of 5 is not according to the priority principle of ITF 6 the Interleaved2 of 5 with the barcode length of 6 characters and the last character as the check character can be read but other...

Page 64: ...ing ITF 14 Allow to Read ITF 14 and Transmit the Check Digit Note if the setup of ITF 14confilits with the setup of Interleaved2 of 5 for example reading ITF 14 is allowed but reading Interleaved2 of 5 is not according to the priority principle of ITF 14 the Interleaved2 of 5 with the barcode length of 14 characters and the last character as the check character can be read but other Interleaved2 o...

Page 65: ...rohibit Reading Deutsche14 thus if the scanner is unable to read the Deutsche14 please try to read the setuo barcode allow to read Deutsche14 Deutsche 14 uses the same coding method as ITF 14 and normal ITF so if all these are used at the same time the misunderstanding of function setup and decoding will easily occure thus it is suggested to turn off the Deutsche 14 if it is not in use CodeID Setu...

Page 66: ...he12 Allow to Read Deutsche12 and send the check digit Note the scanner will become unable to read Deutsche12 by reading the setup barcode Prohibit Reading Deutsche12 thus if the scanner is unable to read the Deutsche12 please try to read the setuo barcode allow to read Deutsche12 Deutsche 12 uses the same coding method as ITF 12 and normal ITF so if all these are used at the same time the misunde...

Page 67: ...ill be restored to the factory default state Restore the Default Setup Value of COOP25 Allow to Read COOP 25 or not Allow to Read COOP25 Prohibit Reading COOP25 Note the scanner will become unable to read COOP25 by reading the setup barcode Prohibit Reading UCC EAN 128 thus if the scanner is unable to read the COOP25 please try to read the setuo barcode allow to read COOP25 CodeID Setup To activat...

Page 68: ...ill be treated as the last bit of the normal data if failed then the scanner will indicate barcode reading failed No Check Check and Send Check Digit Check but do not Send Check Digit Note by setting do not send the check digit if the data length except for the 1 character check digit is less than the minimum barcode reading limit the barcode reading will be failed For example the scanner set the ...

Page 69: ... 5 Restore the Default Value By reading the barcode the parameter setup of Matrix2 of 5 will be restored to the factory default state Restore the Default Setup Value of Matrix2 of 5 Restore the Default Setup Value of Matrix2 of 5 Allow to Read Matrix2 of 5 Prohibit Reading Matrix2 of 5 Note the scanner will become unable to read Matrix2 of 5 by reading the setup barcode Prohibit Reading Matrix2 of...

Page 70: ...eading failed Set Check and Send Check digit the scanner will check according to the last bit if successful all the data including the check digit will be transmitted the check digit will be treated as the last bit of the normal data if failed then the scanner will indicate barcode reading failed No Check Check and Send Check digit Check but do not Send Check digit Note by setting do not send the ...

Page 71: ...the minimum length then the scanner is only able to read the barcode with such length Industrial 25 Restore the Default Value By reading the barcode the parameter setup of Industrial 25 will be restored to the factory default state Restore the Default Setup Value of Industrial 25 Allow to Read Deutsche 12 or not Allow to Read Industrial 25 Prohibit Reading Industrial 25 Note the scanner will becom...

Page 72: ...l all the data including the check digit will be transmitted the check digit will be treated as the last bit of the normal data if failed then the scanner will indicate barcode reading failed No Check Check and Send Check digit Check but do not Send Check digit Note by setting do not send the check digit if the data length except for the 1 character check digit is less than the minimum barcode rea...

Page 73: ...tup of Standard 25 will be restored to the factory default state Restore the Default Setup Value of Standard 25 Allow to Read Standard 25 or not Allow to Read Standard 25 Prohibit Reading Standard 25 Note the scanner will become unable to read Standard 25 by reading the setup barcode Prohibit Reading Standard 25 thus if the scanner is unable to read the Standard 25 please try to read the setuo bar...

Page 74: ...igit will be transmitted the check digit will be treated as the last bit of the normal data if failed then the scanner will indicate barcode reading failed No Check Check and Send Check digit Check but do not Send Check digit Note by setting do not send the check digit if the data length except for the 1 character check digit is less than the minimum barcode reading limit the barcode reading will ...

Page 75: ...ed to the factory default state Restore the Default Setup Value of Code 39 Allow to Read Code 39 or not Allow to Read Code 39 Prohibit Reading Code 39 Note the scanner will become unable to read Code 39 by reading the setup barcode Prohibit Reading Code 39 thus if the scanner is unable to read the Code 39 please try to read the setuo barcode allow to read Code 39 CodeID Setup To activate the setup...

Page 76: ...l indicate barcode reading failed No Check Check and Send Check digit Check but do not Send Check digit Note by setting do not send the check digit if the data length except for the 1 character check digit is less than the minimum barcode reading limit the barcode reading will be failed For example the scanner set the the minimum barcode reading length of Code 39 to 4 characters and do not send ch...

Page 77: ... 255 if the maximum length is shorter than the minimum length then the scanner is only able to read the barcodes with the minimum length and the the maximum length if the maximum length equals to the minimum length then the scanner is only able to read the barcode with such length Example The steps of set the scanner read the Code 39 with barcode length between 8 to 12 characters 1 Read the Start ...

Page 78: ...appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the Exit Setup barcode Check Setup Codabar barcode data does not compulsively include the check digit if check digit exists then it is the last character Check digit is calculated according to all the datas for checking if the data is correct or not Set No Check the scanner will transmit all the barcode data S...

Page 79: ...Setup Do not Send the Start and Stop Character Send the Start and Stop Character Set ABCD ABCD as the Start and Stop Character Set ABCD TN E as the Start and Stop Character Set abcd abcd as the Start and Stop Character Set abcd tn e as the Start and Stop Character Set the Barcode Reading Length The scanner is only able to read the Codabar with tramsmission content length falls in the limited range...

Page 80: ...um Length Limit 3 Read the numeric barcode 8 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the barcode of Set the Maximum Length Limit 6 Read the numeric barcode 1 7 Read the numeric barcode 2 8 Read the Save barcode see the appendix numeric barcode 9 Read the Exit Setup barcode Code 93 Restore the Default Value By reading the barcode the paramete...

Page 81: ...it all the barcode data Set Check but do not Send Check digit the scanner will check according to the last bit if successful all the data except for the check digit will be transmitted if failed then the scanner will indicate barcode reading failed Set Check and Send Check digit the scanner will check according to the last bit if successful all the data including the check digit will be transmitte...

Page 82: ...h Limit Note the maximum length limit of any 1D barcode must not exceed 255 if the maximum length is shorter than the minimum length then the scanner is only able to read the barcodes with the minimum length and the the maximum length if the maximum length equals to the minimum length then the scanner is only able to read the barcode with such length Code 11 Restore the Default Value By reading th...

Page 83: ...ic barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the Exit Setup barcode Check Setup Code 11 barcode data does not compulsively include the check digit if check digit exists then it is the last character Check digit is calculated according to all the datas for checking if the data is correct or not Set No Check the scanner will transmit all the barcode data No Check One Di...

Page 84: ... Length Limit to adjust the minimum length limit Read the barcode of Set the Maximum Length Limit to adjust the maximum length limit Set the Minimum Length Limit Set the Minimum Length Limit Note the maximum length limit of any 1D barcode must not exceed 255 if the maximum length is shorter than the minimum length then the scanner is only able to read the barcodes with the minimum length and the t...

Page 85: ... will be set to the CodeID Code ID Setup Example Set the CodeID ofPlesseyto p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the Exit Setup barcode Check Setup Plessey barcode data does not compulsively include the check digit ...

Page 86: ... tramsmission content length falls in the limited range the range is consisted of the maximum value and minimum value in units of character the Plessey exceeds the range can not be read or transmitted Read the barcode of Set the Minimum Length Limit to adjust the minimum length limit Read the barcode of Set the Maximum Length Limit to adjust the maximum length limit Set the Minimum Length Limit Se...

Page 87: ...the hexadcimal value inaccordance with the character which will be set to the CodeID Code ID Setup Example Set the CodeID ofMSI Plesseyto p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the Exit Setup barcode Check Setup MSI P...

Page 88: ...le to read the MSI Plessey with tramsmission content length falls in the limited range the range is consisted of the maximum value and minimum value in units of character the MSI Plessey exceeds the range can not be read or transmitted Read the barcode of Set the Minimum Length Limit to adjust the minimum length limit Read the barcode of Set the Maximum Length Limit to adjust the maximum length li...

Page 89: ... Databar please try to read the setuo barcode allow to read GS1 Databar CodeID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID Code ID Setup Example Set the CodeID ofGS1 Databarto p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric...

Page 90: ...e setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID Code ID Setup Example Set the CodeID ofPDF417to p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5...

Page 91: ...e MicroPDF417 support the barcode with maximum 255 bytes CodeID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID Code ID Setup Example Set the CodeID ofMicroPDF417to p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 se...

Page 92: ... non stop Set the Time Interval between Scanning 1 second Range 0 7 5sec Sensitivity Level High Sensibility Effective in Sensitivity Mode Security Level Level 1 Decoding Sound Intermediate Frequency Loud 150ms Tone fo Successful Reading Read the Same Barcode successivly Off Effective in Auto Mode Re Timing after Successful Reading On Effective in Auto Mode Communication Setup Baud Rate 9600 Serial...

Page 93: ...efix sequence CodeID Custom AIMID CodeID Prefix AIMID Data Suffix Terminal Add AIMID Prefix Off Cm Symbol Add CodeID Off 1 or 2 Character Captital or Lowercase Letter Add Custom Prefix Off The Maximum is 11 characters Add Custom Suffix Off The Maximum is 11 characters Barcode Parameter Setup Code128 Enable On Maximum Length 255 Minmum Length 1 UCC EAN 128 Enable On Maximum Length 255 Minmum Length...

Page 94: ...ff Extracode is Required 5 digits Off Extend to EAN 13 Off Type is EAN 13 when Extend Off EAN 13 Enable On Send the Check Character On Read 2 Digits Extracode Off Read 5 Digits Extracode Off Extracode is Required 2 digits Off Extracode is Required 5 digits Off ISSN Enable Off ISBN Enable Off Use 10 digits ISBN Off UPC E Enable On Send the Check Character On Read 2 Digits Extracode Off ...

Page 95: ... UPC A when Extend Off Send the System Digit 0 UPC A Enable On Send the Check Character On Read 2 Digits Extracode Off Read 5 Digits Extracode Off Extracode is Required 2 digits Off Extracode is Required 5 digits Off Send the System Digit 0 Interleaved 2 of 5 Enable On Check On Send Check Character Off Maximum Length 255 Minmum Length 6 ITF 6 Enable Off Send Check Character On ITF 14 ...

Page 96: ...er On Deutshe 12 Enable Off Send Check Character On COOP25 JapaneseMatrix 2 of 5 Enable Off Check Off Send Check Character Off Maximum Length 255 Minmum Length 6 Matrix 2 of 5 European Matrix 2 of 5 Enable On Check Off Send Check Character Off Maximum Length 255 Minmum Length 6 At less 3 Industrial 25 Enable Check Send Check Character ...

Page 97: ... Maximum Length 255 Minmum Length 6 At less 4 Code 39 Enable On Check Off Send Check Character Off Do not Send Start and Stop Character Off Support Full ASCII On Maximum Length 255 Minmum Length 4 Codabar Enable On Check Off Send Check Character Off Do not Send Start and Stop Character Off Select one ABCD ABCD as the Start and Stop Character On ...

Page 98: ...Off Maximum Length 255 Minmum Length 4 At less 2 Code 93 Enable On Check On Send Check Character Off Maximum Length 255 Minmum Length 2 At less 1 Code 11 Enable Off Check Off Send Check Character On 1 Digit MOD10 Check On 2 Digits MOD10 MOD10 Check Off 2 Digits MOD10 MOD11 Check Off Auto 2 Digits MOD11 MOD11 Off Auto 2 Digits MOD11 MOD9 Off Maximum Length 255 Minmum Length 4 At less 3 Plessey ...

Page 99: ...r Off Maximum Length 255 Minmum Length 4 At less 4 MSI Plessey Enable Off Check Off Send Check Character On 1 Digit MOD10 Check Off 2 Digits MOD10 MOD10 Check Off 2 Digits MOD10 MOD11 Check Off Maximum Length 255 Minmum Length 4 At less 3 GS1 Databar Enable On PDF417 Enable On MicroPDF417 Enable On ...

Page 100: ...IM 128 C2 ISBT 128 C4 EAN 8 E4 EAN 13 E0 EAN 13 with Addon E3 ISSN X0 ISBN X0 UPC E E0 UPC E with Addon E3 UPC A E0 UPC A with Addon E3 Interleaved 2 of 5 Im 0 1 3 ITF 6 Im 1 3 ITF 14 Im 1 3 Deutsche 14 X0 Deutsche 12 X0 COOP 25 Japanese Matrix 2 of 5 X0 Matrix 2 of 5 European Matrix 2 of 5 X0 Industrial 25 S0 ...

Page 101: ... 2 4 Code 93 G0 Code 11 Hm 0 1 3 Plessey P0 MSI Plessey Mm 0 1 GS1 Databar e0 PDF417 Lm 0 1 2 MicroPDF417 Lm 3 4 5 Reference 1 ISO IEC 15424 2008 2 Information Technology Auto Identification and Data Cellection Technology Data Carrier Identifiers including the symbol identifiers ...

Page 102: ... EAN 128 u AIM 128 f ISBT 128 t EAN 8 g EAN 13 d ISSN n ISBN B UPC E h UPC A c Interleaved 2 of 5 e ITF 6 r ITF 14 q Deutsche 14 w Deutsche 12 l COOP 25 Japanese Matrix 2 of 5 o Matrix 2 of 5 European Matrix 2 of 5 v Industrial 25 i Standard 25 s Code 39 b Codabar a Code 93 y ...

Page 103: ... Exit Setup 93 Code 11 z Plessey p MSI Plessey m GS1 Databar R PDF417 P MicroPDF417 M Data Barcode After reading the data barcode please read save in the next page to svae the data barcode setup 0 4 1 5 2 6 3 7 8 9 ...

Page 104: ...data 1 2 3 according to priority after that If the scanner read Abort the Last Data then the last digit 3 will be aborted if read Abort a String of Data then the data 123 will be aborted if read Abort the Present Setup then the data 123 and the setup barcode will all be aborted and the scanner is still in the state of Enter Setup Barcode Save Data Parameter Abort the Present Command Abort one of t...