Start Setup
】
38
【
Exit Setup
】
Read the barcode of “Set the Minimum Length Limit” to adjust the minimum length limit
Read the barcode of “Set the Maximum Length Limit” to adjust the maximum length limit
Set the Maximum Length Limi
Set the Minimum Length Limit
Note
:
the maximum length limit of any 1D barcode must not exceed 255, if the maximum length is shorter than the
minimum length, then the scanner is only able to read the barcodes with the minimum length and the the maximum length;
if the maximum length equals to the minimum length, then the scanner is only able to read the barcode with such length.
Example: Set the scannerread the UCC/EAN-128 with barcode length between 8 to 12 characters.
1.
Read the
“Start Setup” barcode.
2.
Read the barcode of “Set the Minimum Length Limit”.
3.
Read the numeric barcode “8”, (see the appendix—numeric barcode)
4.
Read
the “Save” barcode. (see the appendix—numeric barcode)
5.
Read the barcode of “Set the Maximum Length Limit”.
6.
Read the numeric bar
code “1”.
7.
Read the numeric barcode “2”.
8.
Read
the “Save” barcode.(see the appendix—numeric barcode)
9.
Read the
“Exit Setup” barcode.
AIM 128
Restore Default Value
By reading the barcode, the parameter setup of UCC/EAN-128 will be restored to the factory default state.
Restore the Default Setup Value of UCC/EAN-128
AIM 128 Allow to Read AIM-128 or not
Allow to Read AIM-128
Prohibit Reading AIM-128
Note:the scanner will become unable to read AIM-
128 by reading the setup barcode “Prohibit Reading AIM-128”, thus, if
the scanner is unable to read the AIM-
128, please try to read the setuo barcode “allow to read AIM-128”.
Summary of Contents for NLS-HR15XX-30
Page 1: ...NLS HR15Series NLS HR15XX 30 Corded 1D Barcode Scanner User Guide ...
Page 9: ...Save and Abort the Setup 94 ...
Page 10: ......
Page 18: ...8 Reading Depth of Field ...
Page 25: ... Start Setup Exit Setup 15 SetupProcess Flow ...
Page 37: ... Start Setup Exit Setup 27 USB Virtual Serial Port Function USB Virtual Serial Port Function ...