- 28 -
www.NewLeader.com
(800) 363-1771
301321-AA-I
SUPER P
Installation Instructions Continued
Cab Control Installation
When selecting a location for the spreader controls, consider the following:
1� Select a suitable location in the cab to mount the control, where it is easily accessible and visible to
operator without obstructing normal driving view�
2� Check clearance with the driver’s seat in all positions�
3� Check clearance with the transmission gear shift in all positions�
4� Check clearance with any other controls, such as parking brake or plow and wing controls�
5� For hydraulic control, check underneath cab for clearance with transmission and linkages, exhaust,
etc�
6� Ensure that the control does not interfere with entering or leaving the cab�
All holes in truck cab walls, floor and firewall are to be grommeted, plugged and sealed
to prevent entrance of engine fumes, dust, dirt, water and noise� Failure to follow this
requirement may result in injury or machine damage�
Engine Drive
Control Panel
All wiring should be approved automotive insulated wire, secured adequately with insulating ties or
straps, and located where it will not interfere with any control or access� Grommet all holes where wiring
passes through cab floor or firewall to prevent wiring damage. Make sure wiring does not contact any
moving parts or sharp edges and is kept away from hydraulic lines and heated parts�
7� Once control panel is properly mounted, route
the engine control cable out of the cab to the
left hand rear of the truck�
8� Install the supplied connector mounting
bracket to the truck body where the engine
harness can easily be connected�
9� Feed the cable from the cab control through
the center hole of the mounting bracket, and
trim to length as necessary�
10� Assemble connector to end of cab control
harness as shown in Figure 4 and secure in
mounting bracket�
WIRE CONNECTIONS
VIEWED FROM REAR
5=RED
1=WHITE
2=BLUE
6=BROWN
4=BLACK
3=GREEN
7=YELLOW
(WITH INSERT)
Figure 4