SDI-IP-GTW User Manual
49
3.7.1.5
IP RX Status
Locked:
Indicates "Yes" when the unit has locked to the input stream
and is currently playing out a valid SDI stream.
Total rate:
The total IP rate received on this channel.
Current buffer fill:
Shows the number of bytes currently in the buffer.
Latency:
This parameter reflects the current latency in the unit. This
value is directly dependent on the current buffer fill.
RTP sequence errors:
A counter showing the number of RTP sequence
errors caused by lost packets or out-of-order packets. A value of zero
indicates that all packets are received in order.
Lost IP frames:
A counter showing the number of IP frames that is lost,
i.e. lost and not corrected by the unit.
Corrected IP frames:
A counter showing the number of IP frames that
are corrected by the unit.
Reset statistics:
Press this button to reset the counters: Skipped
frames, Repeated frames, RTP sequence errors and Lost IP frames.
3.7.2
FEC Settings
Figure 24. The FEC sub-page of an IP receiver
This sub-page will only appear if the unit is enabled with FEC
.
Summary of Contents for SDI-IP-GTW
Page 1: ...network electronics com SDI to IP Gateway Rev 1 3 0 Flashlink User Manual SDI IP GTW...
Page 2: ...This page is intentionally left blank...
Page 4: ...SDI IP GTW User Manual 4 This page is intentionally left blank...
Page 8: ...SDI IP GTW User Manual 8 This page is intentionally left blank...
Page 56: ...SDI IP GTW User Manual 56 This page is intentionally left blank...
Page 61: ...SDI IP GTW User Manual 61 Figure 31 Data flow between two units...
Page 62: ...SDI IP GTW User Manual 62 This page is intentionally left blank...