SDI-IP-GTW User Manual
20
connection should be achieved by connecting earth to the additional
technical earth connection on the rear panel of the unit.
Warning:
This unit must be correctly earthed through the moulded
plug supplied. If the local mains supply does not have an earth
conductor do not connect the unit.
Caution:
Consult the supply requirements in Technical Specification
prior to connecting the unit to the supply.
The unit has a Technical Earth terminal located at the rear panel. Its
use is recommended. This is
not
a Protective earth for electrical shock
protection. The terminal is provided to:
1. Ensure all equipment chassis fixed in the rack are at the same
Technical earth potential. To achieve this, connect a wire between the
Technical earth terminal and a suitable point on the rack.
2. Eliminate the migration of stray charges when connecting between
equipment.
Warning:
If the terminal screw has to be replaced, use an M4x12mm
long pozidriv panhead. Using a longer screw may cause a safety hazard.
2.3.2.3
Connecting the Video Gateway to the AC Power Supply
Warning:
Do not overload wall outlets and extension cords as this can
result in a risk of fire or electrical shock. As no mains switch is fitted in
this unit, ensure that the local ac power supply is switch off before
connecting the supply cord. The unit is not fitted with an on/off switch.
Ensure that the socket-outlet is installed near the equipment so that is
easily accessible. Failure to isolate the equipment properly may cause a
safety hazard.
To connect the unit to the local AC power supply:
1. Ensure that the local ac power supply is switch OFF.
2. Connect the ac power lead to the Video Gateway mains input
connector and then the local mains supply.
2.4
Signal Connections
2.4.1
Introduction
All signal connectors are located at the rear of the SDI-IP-GTW. For
detailed specifications of the different interfaces, please refer to Chapter
5.6Appendix B.
Please ensure that specified cables are used in order to ensure signal
integrity and compliance with EMC requirements.
Summary of Contents for SDI-IP-GTW
Page 1: ...network electronics com SDI to IP Gateway Rev 1 3 0 Flashlink User Manual SDI IP GTW...
Page 2: ...This page is intentionally left blank...
Page 4: ...SDI IP GTW User Manual 4 This page is intentionally left blank...
Page 8: ...SDI IP GTW User Manual 8 This page is intentionally left blank...
Page 56: ...SDI IP GTW User Manual 56 This page is intentionally left blank...
Page 61: ...SDI IP GTW User Manual 61 Figure 31 Data flow between two units...
Page 62: ...SDI IP GTW User Manual 62 This page is intentionally left blank...