Specifications
Power
101E
,
101F
: 230V~; 50Hz; 16A
101J
: 230V~; 50Hz; 10A
101S
: 110/230V~; 60/50Hz; 10A
101G
: 230V~; 50Hz; 13A
101B
: 110V~; 60Hz; 15A
Swit ched out put s
101E
,
101F
: 230V~; 50Hz; 16[8]A; max. 3600W
101J
: 230V~; 50Hz; 10[8]A; max. 2300W
101S
: 110/230V~; 60/50Hz; 10[8]A; max. 2300W
101G
: 230V~; 50Hz; 13[8]A; max. 3000W
101B
: 110V~; 60Hz; 15[8]A; max. 1600W
Surge prot ect ion
Type 3 (CAT III)
Int ernal consumpt ion
Max 1W
Out put relay
Micro-disconnection (µ) (resistive load)
1E5 switching cycles, max. 1.5kV pulse voltage
Switch heat and fire resistance class 1
Elect rical load
ZCS
(Zero Current Swit ching)
- Resist ance load compat ible
- Capacit ive load compat ible
- Induct ive load compat ible
Int erf aces
PowerCable xxx 101x
1x Wi-Fi 802.11b/g/n 2.4 GHz (internal antenna)
with WEP/WPA/WPA2
Environment
IP30, protection rating = class 1
Operating temperature -20 .. 65°C (6A load = max. 63°C,
10A = max. 50°C, 16A = max. 30°C)
Device rated for pollution degree 2.
Designed for continuous operation in altitudes up to 2000m.
No additional cooling required.
Caution
The device is not designed to power appliances with a high inrush
current.
Do not connect several devices in series.
The device is safe only when completely disconnected from the
electrical network. The cable plug serves as the disconnection means
and must be easily accessible.
The electrical socket must be earthed and protected with a circuit
breaker rated at 16A or less.
Summary of Contents for PowerCable Modbus 101 Series
Page 3: ...3 ...
Page 13: ...13 4 3 Drawings Figure 7 PoweCable xxx 101x side view Figure 8 PoweCable xxx 101x t op view ...
Page 28: ...28 Figure 27 Reset t ing t he consumpt ion count er ...
Page 44: ...44 7 PowerCable REST 101x 7 1 Overview Only one protocol can be active ...
Page 59: ...59 8 PowerCable Modbus 101x 8 1 Overview Only one protocol can be active ...
Page 69: ...69 9 PowerCable MQTT 101x 9 1 Overview Only one protocol can be active ...