8. 3
M2M API Protocol – Telnet
Available only in PowerCable MODBUS 101x
Fi gur e 42 –Tel net pr ot ocol conf i gur at i on
Enable T elnet
Enables M2M Telnet f unct ions in t he syst em kernel.
Port
Specif ic port f or Telnet only, range 1 – 65535. Be aware, t hat you
should ent er value, which is not already occupied by anot her M2M
prot ocol or web int erf ace.
Enable READ-ONLY
Enables
Read-Only
access via M2M Telnet API f or monit oring. You may
also f ill in t he username and password f or t his mode.
Enable READ-WRIT E
Enables
Read/ Write
access f or monit oring and out put cont rol. You may
also f ill in t he username and password f or t his mode.
Username
Username f or t he respect ive access mode (Read-Only/ ReadWrit e). Not e
– t his is unrelat ed t o t he username f or accessing t he PowerCable web
administ rat ion. When lef t empt y, t he prot ocol will not require any
aut hent icat ion.
Password
Password f or t he corresponding username (Read-Only/ ReadWrit e).
Save Changes
Saves t he changes.