36
6. 5. 2
Net work Conf igurat ion
This sect ion allows conf iguring t he IP paramet ers of t he PowerCable net work int erf ace which are
essent ial f or correct net work operat ion.
Fi gur e 30 – Net wor k conf i gur at i on
MAC address
Et hernet address of t he net work adapt er. Unique f or each device. Also
corresponds t o t he PowerCable serial number.
St at us
Connect ion st at us
Use DHCP
When select ed, t he device at t empt s t o obt ain net work conf igurat ion
f rom a DHCP server. If your net work does not use DHCP, set t he
paramet ers st at ically.
Set st at ic IP address
Manual conf igurat ion of net work paramet ers. Select t his opt ion if your
net work does not have a DHCP server.
IP address
Choose an unused IP address in your net work’ s address range.
Net mask
Set t he net work mask according t o your net work’ s address range.
Def ault gat eway
Address of t he net work gat eway. Corresponds t o t he address of your
rout er’ s LAN int erf ace.
DNS server
IP address of t he domain name server. It is usually t he same as t he
gat eway address, as long as t he DNS f unct ion is enabled on t he rout er. If