26
The
Reset
but t on swit ches t he out put of f and t hen back on. A conf irmat ion is request ed bef ore
t he act ion is perf ormed. The f unct ion is enabled only when t he out put is swit ched on. When t he
out put is swit ched of f , t he Reset but t on is disabled.
Click
Reset
t o conf irm t he act ion or
Cancel
t o cancel it .
To suppress t his dialog in t he f ut ure, check
Don’ t ask me again
.
6. 1. 1
Out put s - Energy measurement s
PowerCable measures t he f ollowing elect rical paramet ers every 500ms. The display in t he web
int erf ace is updat ed every 5 seconds.
Fi gur e 25 – Measur ed val ues
Load
in wat t s [
W
] corresponds t o t he immediat e current and volt age (P = U * I * TPF).
Current
in amps [
A
] shows t he immediat e current f lowing t hrough t he out put .
TPF (True Power Factor)
shows t he rat io of act ive and apparent power, or t he rat io of resist ance
and impedance. A value less t han 1 means t hat t here is a phase dif f erence bet ween t he current and
t he volt age, i. e. higher energy losses compared t o a purely resist ive load.