background image

3

 

3M™ No Polish LC JG1 Connector  for 1.6-2 mm cable 

8832-JG1 UPC SM 
6832-50/OM2-JG1 MM 
6832-50/OM4-JG1 MM 

 

Instructions 

January 2016 

 

OPT01

-

IN

-

178B(E)

 

Summary of Contents for 6832-50/OM2-JG1 MM

Page 1: ...3 3M No Polish LC JG1 Connector for 1 6 2 mm cable 8832 JG1 UPC SM 6832 50 OM2 JG1 MM 6832 50 OM4 JG1 MM Instructions January 2016 OPT01 IN 178B E ...

Page 2: ...mediately flush eyes with water while holding eyelids open and continue flushing for ten minutes Contact a physician Upon skin contact wash with soap and water Refer to Safety Data Sheet for product information CAUTION To reduce the risk associated with handling sharp glass fibers Cleaved glass fibers are sharp and can pierce the skin Use tweezers when handling shards and dispose of them properly ...

Page 3: ...isposable stripper for 250um coating removal only up to 20 stripping Note content may vary depending on product you purchased Other tools F Fiber cleaver G Fiber Stripper H Alcohol I Lint free wipe J Snips Note Carefully follow safety health and environmental information given on product labels or the Safety Data Sheets for isopropyl alcohol fiber optic cleaning solution A B C D ...

Page 4: ...ainst the stop on the cable holder as shown Group aramid yarn and insert into one of the slot next to the stop 2 2 Remove cable jacket 50mm from the cable end Cable holder can be used to measure the length Align the end of cable to the double line on the cable holder to meas ure 50mm ...

Page 5: ...te position in the clamp depending on fiber type inside cable jacket And close the cover to clamp cable Upper position cable with 900um coated fiber inside Lower position cable with 250um coated fiber inside Make sure fiber sit in fiber guide slit in sliding connect or nest Slit ...

Page 6: ...rking 2nd marking 900um fiber only 2 6 Bring the sliding nest back to original position Strip buffer coating using appropriate stripping tool Stripping 250µm fiber using disposable stripper Place cable holder on the stripper such that cable holder butt up against the stop Close the stripper and pull out the cable holder Abut cable holder against stop Caution Do NOT OVERUSE the stripper up to 20 st...

Page 7: ... dispose of broken off piece and repeat at Step 2 2 Note Do not touch bare glass 10mm from buffer end 2 9 Place the cable holder on a cleaver and push it to the stop Cleave the fiber per cleaver manufacture s instruc tion Note If cleave length gauge is installed on your cleaver remove the gauge prior to connector installation Save the cleave length gauge for later use Holder butt up against stop S...

Page 8: ...oo long Right length Fiber end buffer end must be within respective gauge window 900µm buffer shown as example 2 11 Pull out buffer clamp to release buffer 2 12 Remove connector from the plastic bag Attach the connector to sliding connector nest with splice cap facing up Pinch side of sliding connector nest to allow fiber guide protrude downward see Section 2 13 ...

Page 9: ...ion Do NOT TOUCH CABLE until splice is actuated at Section 2 17 2 13 Be aware of fiber guide protruding downward until splice is acutated Caution Do NOT PUSH UP fiber guide or connector may pop out from cable holder 2 16 Check for marking on buffer at the end of buffer clamp If marking is not at this position pull out the sliding head and check for fiber length again per Section 2 10 And insert fi...

Page 10: ...tuation lever on the dust cap and fully press down the lever 2 18 Check if cap is fully actuated If not press down lever again 2 19 Slide boot next to the holder 2 20 Release holder cover and bring boot closer to connector ...

Page 11: ... holder Caution Keep holding aramid yarn and connector togeth er until boot is secured to the connector Failure to do so may induce twist in fiber resulting in fiber break later 2 23 WHILE HOLDING ARAMID YARN AND CONNECTOR TOGETHER WITH ONE HAND take about half of aramid yarn with another hand and bring it to the bottom side of connector ...

Page 12: ...R 2 26 Trim off excess aramid yarn with snips Termination completed 2 24 Bring boot up to connector Caution Keep holding aramid yarn and connector togeth er until boot is secured to connector Failure to do so may induce twist in fiber resulting in fiber break later No Gap Gap ...

Page 13: ... can be duplexed without using extra parts Two connectors can dovetail together to form duplex connector 3 2 Identify dovetailing features on both sides of connector body 3 3 Dovetail two connectors to assemble them together 3 4 Make sure latches are fitting together ...

Page 14: ...onnector re open 4 1 Insert two folks on the dust cap into slots on back side of connector 4 2 Unscrew and remove boot from connector 4 3 Pull out buffer clamp with fingers then remove fiber from the connector ...

Page 15: ...tion Markets Division 3M Telecommunications www 3M com Telecom 3M 2016 All rights reserved Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of 12 months from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FIT NESS FOR A PARTICULAR PURPOSE If this produ...

Reviews: