82
NED
XCM8085DLMT8
UME-0060-04
8.6.2 Clock & Integration
『
Clock & Integration
』
tab.
Clock
: Shows the camera internal clock frequency.
Note: Read Only
(The input of the counter value and padding value are effective at 85MHz and
40MHz on these displays but the camera internal clock frequency is effective only
at 85MHz on the display. )
Integration Time
: Setting integration time. (unit:
μs)
Dividing
: 1 (fixed)
Counter
: Sets a counter value with the slider, edit-box or the spin-button. Then, click
“Send” button.
Padding
: Sets a counter value with the slider, edit-box or the spin-button. Then, click
“Send” button.
Padding time
: Shows the calculated value of the Padding. (unit:
μs )
Scanrate
:
Shows the calculated value of the scan rate. (unit:
μs )
Scanrate -> Counter
automatic setting
:
The Counter value of Clock, Diving, and Padding is calculated and set from the
present value when the scanning cycle is set and then clicking on the
“Scanrate->Counter Calculating” button.