4.2.16 Setting
OutputSignal 1
Sets the data format of output signals.
Format 3
CMD
□
VAL1
□
VAL2 CR
CMD
voa
VAL 1
0,1 (output data 8bit / 10bit switching)
<Example>
voa
□
0
□
0 CR (8bit output)
>OK
>voa 0
4.2.17 Setting
OutputSignal 2
Sets the camera output signal to Single Line / Dual Lines / 2x2 binning.
Format 2
CMD
□
VAL1 CR
CMD
vod
VAL 1
0 : Dual Lines Mode(average) (*1)
1 : Dual Lines Mode(addition) (*1)
2 : Single Line Mode(line A)
3 : Single Line Mode(line B)
4 : 2x2 binning Mode(average=Total output value of 4 pixels
÷
4) (*2)
5 : 2x2 binning Mode(addition=Total output value of 4 pixels) (*2)
6 : 2x2 binning Mode(Total output value of 4 pixels
÷
2) (*2)
(*1) Set the delay value using
the “d” command at the Dual Lines-modes.
See 4.2.18 Setting Line Delay.
(*2) Set the value of output using
the “tap” command at 2 or 4 on 2x2 binning modes.
See 4.2.20 Setting Output TAP Number.
Note:
Make sure that the
“disp” command is set at 0 for one display.
If the
“disp” command is set at 1, the setting of the “vod” command is ignored
on this outputsignal2 setting.
<Example>
vod
□
1 CR
(
Dual Line Mode (average)
)
>OK
>vod 1