41 NED
XCM
4085TLCT6
UME-0062-01
4.8.3
External Trigger Exposure Mode (Trigger Level)
In external trigger exposure mode (Trigger Level), the exposure time is
determined by the high trigger pulse time, each exposure starts with the rising edge
and the line period is determined by the time rising edge to rising edge of trigger
pulse. The range of programmable exposure time, the timing chart of the exposure
and the readout are shown below.
Table 4-8-3-1 Programmable Exposure Time (Trigger Level)
Item
Symbol
XCM4085TLCT6
Readout time
R
Data output at each colour
at 85MHz 2taps
:
24.10
at 85MHz 1tap
:
48.19
at 40MHz 2taps
:
50.73
at 40MHz 1tap
:
101.45
Trigger pulse H time (Exposure Time)
T1
≧
22.12
Trigger pulse L time
T2
≧
2.86
Trigger pulse cycle (Scan Rate)
T3
The value of trigger pulse cycle
must be as follows.
Data output at each colour
at 85MHz 2taps
:
≧
24.98
at 85MHz 1tap
:
≧
49.22
at 40MHz 2taps
:
≧
52.79
at 40MHz 1tap
:
≧
103.44
(unit
:
μs)
Figure 4-8-3-1 External Trigger (Trigger Level) Exposure Mode
T1
T2
T3
R
T1
外部トリガ信号
入力(CC1)
露光
読み出し
LVAL
Exposure
Readout
LVAL
External
Trigger Signal
Input(CC1)