33 NED
XCM
4085TLCT6
UME-0062-01
4.2.18 Setting Gamma correction
Switches Gamma correction value.
●
Format S2 CMD
□
VAL1 CR
,
Format R1 >R CR >[SB] CR EOT
●
CMD
gamma
●
VAL
0,1,2,3
(
0:Off(1.0),1:0.45, 2:0.56 3: Reverse Negative-Positive
)
<Example> Set the gamma adjustment to 0.45
Send
:
gamma
□
1 CR
Receive
:
>OK CR > bin
□
1 CR EOT
4.2.19 Memory Initializing (Initializing Camera Settings)
Reset the flash memory to the factory default.
Format S1 CMD CR, Format R2 >R CR >[MEM] CR >[SB] CR EOT
CMD rst
<Example>
Send
:
rst CR
Receive:
:
>OK CR >Type=XCM4085TLCT6 CR >Ver.= 1.10_0xff14 CR
>Serial=0 CR
>gax 0 CR >gdxr 0 CR >gdxg 0 CR >gdxb 0 CR
>odx 0 CR >odxr 0 CR >odxg 0 CR >odxb 0 CR
>inm 0 CR >int 64,200 CR >dep 8 CR >tap 2 CR
>tpn 0 CR >ldly 2 CR >ldlys 0 CR >shc 1,0 CR
>MFr 768 CR >MFg 768 CR >MFb 768 CR
>MUr 768 CR >MUg 768 CR >MUb 768 CR
>MVr 768 CR >MVg 768 CR >MVb 768 CR
>rev 0 CR >clkcl 85 CR >gamma 0 CR >rst CR EOT
4.2.20 Memory Load
Reads out the camera settings from the flash memory.
Format S1 CMD CR, Format R2 >R CR >[MEM] CR >[SB] CR EOT
CMD rfd
<Example>
Send
:
rfd CR
Receive:
:
>OK CR >Type=XCM4085TLCT6 CR >Ver.= 1.10_0xff14 CR
>Serial=0 CR
>gax 0 CR >gdxr 0 CR >gdxg 0 CR >gdxb 0 CR
>odx 0 CR >odxr 0 CR >odxg 0 CR >odxb 0 CR
>inm 0 CR >int 64,200 CR >dep 8 CR >tap 2 CR
>tpn 0 CR >ldly 2 CR >ldlys 0 CR >shc 1,0 CR