54 NED
XCM
4085TLCT6
UME-0062-01
(3) Capture images using a camera interface board utility. In case of Matrox
’s Solios, it
is convenient to use Intellicam.
Figure 5-2-3 Solios Intellicam dcf Window
5.3 In Operation
(1) Does acquisition time out error occur?
<Cause>
①
Captured images are too heavy.
Note: If there are many filtering processes, the assignments to the driver may be
insufficient.
②
The cables are detached from the connector.
Note: that the power cable and Camera Link cables are connected to the
camera correctly.
③
Camera Link cables come under the influence of noise when the cables are
laid near a light source inverter line or a power line.
Note: The personal computer in use may be reset.
(2) Are there dark lines in the direction of vertical scanning on the image?
<Cause>
Dust on the sensor window.
Note: Dust may come on the sensor window from the inside or the outside of the
camera. Remove the dust with air or a lens cleaner.