1 - 102
Code Restriction Class Assignment when Lockout is Set
NEC Business Solutions Ltd
Xen Master & Xen Axis
A
6
-324000-
642-
02 - Release 6.0
May 20
03
1-1-70
System Mode
1
Submode
1
Data No.
70
PC Programming
a
+AC
Code Restriction Class Assignment
when Lockout is Set
General Description
Use this Memory Block to assign the Code Restriction Class when a station user sets the
Station Lockout or when the Attendant sets Attendant Station Lockout.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 +
LK1 +
GK
to access the Memory Block.
3
Used dial pad to enter class restriction.
Note:
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
Default Values
Class 01
4
Press
N
to write selected data.
5
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
Refer to Section 6 Code Restriction in this chapter.
N
When a station is locked out, the Code Restriction Class Assignment of this Memory Block is used instead of the Code
Restriction Class assigned in Memory Block 4-07, Code Restriction Class Assignment (Day Mode) or 4-08, Code
Restriction Class Assignment (Night Mode).
7 0 : R E S T
C L A S S = 0 1
T I M E
D I S P L A Y
Data
No.
Title
1~7
Setting
Data