Bounce Protect Time Selection
1 - 137
Programming Manual
May 2003
A6-
324000-6
42-02 -
Release 6.0
May 2003
1-3-01
System Mode
1
Submode
3
Data No.
01
PC Programming
a
+BTI
Bounce Protect Time Selection
General Description
Use this Memory Block to specify the time before a valid hookflash is detected from a
Single Line Telephone or Voice Mail system.
Display
Settings
(Page 1)
LK 1
LK 2
LK 3
LK 4
The shaded area indicates the default setting.
0 ms.
100 ms.
200 ms.
300 ms.
LK 5
LK 6
LK 7
LK 8
400 ms.
500 ms.
600 ms.
700 ms.
(Page 2)
LK 1
LK 2
LK 3
LK 4
800 ms.
900 ms.
1000 ms.
1100 ms.
LK 5
LK 6
LK 7
LK 8
1200 ms.
1300 ms.
1400 ms.
1500 ms.
Programming Procedures
1
Go off-line.
2
Press LK1 + LK3 +
KA
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
Hookflash Start Time Selection
N
Bounce Protect Time should be equal to Hookflash Start Time in Memory Block 1-3-05 Hookflash Start Time Selection.
0 1 : B N C E
3 0 0 m s | 1
T I M E
D I S P L A Y
Page
No.
Setting
Data
Title
Data
No.