APR Hookflash Selection
NEC Business Solutions Ltd
Xen Master & Xen Axis
A
6
-324000-
642-
02 - Release 6.0
May 20
03
4-56
System Mode
4
Submode
—
Data No.
59
PC Programming
a
+BTM
APR Hookflash Selection
General Description
Use this Memory Block to allow/deny Hookflash for an Analogue Port Adapter (APR) on a
Multiline Terminal.
System Software S5500 or higher is required.
Display
Settings
LK 1
LK 2
LK 3
LK 4
The shaded area indicates the default setting.
NO
YS
LK 5
LK 6
LK 7
LK 8
Programming Procedures
1
Go off-line.
2
Press LK4 +
EI
to access the Memory Block.
3
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or Tel Port No.
– OR –
R
to go to next assigned Tel Port No.
Q
+1 to enter A for Port Numbers 100~109
Q
+2 to enter B for Port Numbers 110~119
Q
+3 to enter C for Port Number 120
4
Press the corresponding CO/PBX line key to change the setting data option.
5
Press
N
to write the data and display Memory Block 4-1 for next Tel Port No.
6
Program the next Tel Port No. or press
P
To go back on-line.
Related Programming
M.B. Number
Memory Block Name
SLT Hookflash Signal Selection
N
1.
System Software version 5.0 or higher is required to support APR Hookflash.
2.
Operation of SLT connected to APR is the same as the Single Line Telephone.
0 1 / 5 9 : H K
F L S H
N O
T I M E
D I S P L A Y
Tel Port
No.
(01~CO)
Data
No.
Title
Setting
Data