Internal Paging Timeout Selection
1 - 115
Programming Manual
May 2003
A6-
324000-6
42-02 -
Release 6.0
May 2003
1-2-00
System Mode
1
Submode
2
Data No.
00
PC Programming
a
+BP
Internal Paging Timeout Selection
General Description
Use this Memory Block to program the time allowed for paging.
Display
Settings
LK 1
LK 2
LK 3
LK 4
The shaded area indicates the default setting.
90 sec.
120 sec.
No Limit
LK 5
LK 6
LK 7
LK 8
Programming Procedures
1
Go off-line.
2
Press LK1 + LK2 +
KK
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
External Paging Timeout Selection
Internal Zone Paging Selection
N
The six types of paging are:
•
All Internal Zone (51)
•
Internal Zone Paging (52~54)
•
External Zone Paging (all speakers) (55)
•
External Zone Paging (individual speakers) (56~58)
•
Internal/External Zone Paging (59)
0 0 : P A G I N G
9 0 s
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data