Installation Manual, Chapter 5 – Installing Dterm Series i Optional Equipment
121
November 2003, A6-506000-642-01(8508), Release 6.0
3.3.2
Installing AP(A)-R( ) or AP(R)-R( ) Unit on a Multiline Terminal
The AP(A)-R( ) and AP(R)-R( ) Units should be installed
after
the
switch settings have been set.
Note:
If wall mounting the Multiline Terminal, a WM-R( ) Unit must be
used. Refer to
Section 9: Wall Mounting Multiline Terminals on page 1-178
.
1. Prepare Multiline Terminal for adapter installation. Refer to
9: Preparing for Adapter Installation on page 1-109
.
2. Plug the tabs marked
A
and
B
into adapter slots, then snap the
tab on the other end of the adapter into the receptacle marked
C
.
Section 9: Attaching the AP(A)-R( )/AP(R)-R( ) Units to the Multiline
Table 5-3: AP(A)-R( )/AP(R)-R( ) Unit Switch Settings
Switch
Description/Settings
SW1
SW1-1
Connects to Multiline Terminal (Default)
SW1-2
Not Used
SW3
SW3-1
Sets impedance to 600
Ω
for devices such as
modems or facsimile machines.
SW3-2
Used for complex impedance devices such as
Single Line Telephones.
Dip
Switches
(DSW)
DSW 1~8
Leave switches at default