CHAPTER 20 ELECTRICAL SPECIFICATIONS
User’s Manual U13850EJ6V0UD
602
Capacitance (T
A
= 25°C, V
DD
= AV
DD
= BV
DD
= EV
DD
= V
SS
= AV
SS
= BV
SS
= EV
SS
= 0 V)
Parameter
Symbol
Conditions
MIN.
TYP.
MAX.
Unit
Input capacitance
C
I
15
pF
I/O capacitance
C
IO
15
pF
Output capacitance
C
O
f
C
= 1 MHz
Unmeasured pins returned to 0 V
15
pF
Operating Conditions
(1) Operating frequency
AV
DD
Operating Frequency (f
XX
)
V
DD
Note 1
Note 2
BV
DD
EV
DD
Remark
2 to 20 MHz (V850SB1)
4.0 to 5.5 V
4.5 to 5.5 V
4.0 to 5.5 V
4.0 to 5.5 V
4.0 to 5.5 V
2 to 17 MHz (V850/SB1)
4.0 to 5.5 V
4.5 to 5.5 V
4.0 to 5.5 V
3.0 to 5.5 V
3.0 to 5.5 V
2 to 19 MHz (H versions of V850/SB2)
4.0 to 5.5 V
4.5 to 5.5 V
4.0 to 5.5 V
4.0 to 5.5 V
4.0 to 5.5 V
2 to 17 MHz (H versions of V850/SB2)
4.0 to 5.5 V
4.5 to 5.5 V
4.0 to 5.5 V
3.0 to 5.5 V
3.0 to 5.5 V
2 to 13 MHz (A and B versions of V850/SB2)
4.0 to 5.5 V
4.5 to 5.5 V
4.0 to 5.5 V
3.0 to 5.5 V
3.0 to 5.5 V
Note 3
Other than IDLE mode
4.0 to 5.5 V
4.5 to 5.5 V
4.0 to 5.5 V
3.0 to 5.5 V
3.0 to 5.5 V
–
32.768 kHz
IDLE mode
3.5 to 5.5 V
−
4.0 to 5.5 V
3.0 to 5.5 V
3.0 to 5.5 V
Note 4
Notes 1.
When A/D converter is used
2.
When A/D converter is not used
3.
In STOP mode (when only watch timer is operating), V
DD
= 3.5 to 5.5 V. Shifting to STOP mode or
restoring from STOP mode must be performed at V
DD
= 4.0 V min.
4.
Shifting to IDLE mode or restoring from IDLE mode must be performed at V
DD
= 4.0 V min.
(2) CPU operating frequency
Parameter
Symbol
Conditions
MIN.
TYP.
MAX.
Unit
Main clock operation (V850/SB1)
0.25
20
MHz
Main clock operation (H versions of
V850/SB2)
0.25
19
MHz
Main clock operation (A and B versions of
V850/SB2)
0.25
13
MHz
CPU operating frequency
f
CPU
Subclock operation
32.768
kHz