5. Troubleshooting
Express5800/E120d-M Maintenance Guide
30
Chapter 1 Maintenance
[?]
Event ID510:
If the N8103-153 or N8103-162 extra battery is mounted, the following message may be registered in the
RAID log of Universal RAID Utility and OS logs (Windows event log, Linux syslog)
Event source
:
raidsrv
Event ID
:
510
Type
:
Info
Description
:
<RU0510> [CTRL: Number of RAID Controller]
Battery Refresh required.
→
Use Universal RAID Utility to perform battery refresh manually. Refer to
Universal RAID Utility
User's Guide
stored in EXPRESSBUILDER for more information.
[?]
DISK LED flashes
DISK LED flashes frequently even while the Hard Disk Drive is not accessed.
→
When Patrol Read is running, the DISK LED flashes even if the Hard Disk Drive is not being
accessed. If SATA Hard Disk Drive is used, the DISK LED may stay on.
[?]
When N8190-153/154 is used, the names of the Fibre Channel controllers may appear with
different names on Device Manager
When N8190-153/154 is used in Windows Server 2008 R2 or Windows Server 2008, a different
controller name may be displayed per controller in Device Manager. It is not a problem in operating the
system.
To display correct controller name, run the following command stored in the EXPRESSBUILDER DVD
and reboot the system.
Windows Server 2008 R2/Windows Server 2008 x64 Edition:
EXPRESSBUILDER DVD
:\025\win\winnt\ws2008x64\elxstor\friendlyname.exe
Windows Server 2008:
EXPRESSBUILDER DVD
:\025\win\winnt\ws2008\elxstor\friendlyname.exe