1. POST Error Message
Express5800/E120d-M Maintenance Guide
111
Chapter 3 Appendix
Error Message
Cause
Solution
C10B
BMC operational code
corrupted.
Failed to start BMC firmware.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC FRU
corrupted.
An illegality was detected in FRU
containing the device information.
C10E
BMC SDR Repository empty.
An error was detected on BMC SDR.
C10F
IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
C110
BMC FRU device failure.
An error was detected in FRU that
contains device information.
C111
BMC SDR Repository failure.
Failure was detected in SROM that
stores the SDR.
C112
BMC SEL device failure.
Device failure was detected in BMC
SEL.
C113
BMC RAM test error.
An error was detected in BMC RAM.
C114
BMC Fatal hardware error.
A hardware error was detected in
BMC.
C115
Management controller
not responding
Management controller does not
respond.
Update the BMC firmware.
If the same error is detected repeatedly,
contact your sales representative.
C116
Private I2C bus not
responding.
Private I2C bus does not respond.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C117
BMC internal exception
BMC internal error was detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was
detected.
C119
SDR repository corrupt.
BMC error or illegal SDR data was
detected.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C11A
SEL corrupt.
BMC error or illegal system event log
data was detected.
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not installed. Contact your sales representative.
C11C
BMC Mezzanine partition is
invalid.
A format error was detected in BMC
Mezzanine card.
C11D
BMC is in Forced Boot Mode.
Detected that BMC is in Forced Boot
Mode.
Check the jumper switch setting on
motherboard. Unplug the power cord, wait
for at least 30 seconds, then restart the
server. If the same error is detected
repeatedly, contact your sales
representative.
C200
The error occurred during
memory configuration
check.
Memory configuration could not be
obtained.
Contact your sales representative.
C201
Memory Configuration
change is detected.
The memory configuration has
changed since the previous startup.
When
Check previous system Config
is
enabled in
Server
of the setup, this
message appears if the configuration was
changed since the previous startup. If this
message appears even when no
configuration change has been made,
contact your service representative.