134
CHAPTER 10 A/D CONVERTER
User’s Manual U15104EJ2V0UD
(2) Analog input channel specification register 3 (ADS3)
This register specifies the input channel of the analog voltage to be converted.
ADS3 is set with an 8-bit memory manipulation instruction.
Reset input clears this register to 00H.
Figure 10-3. Format of Analog Input Channel Specification Register 3 (ADS3)
ADS33 ADS32 ADS31 ADS30
Specification of analog input channel
0
0
0
0
ANI0
0
0
0
1
ANI1
0
0
1
0
ANI2
0
0
1
1
ANI3
0
1
0
0
ANI4
0
1
0
1
ANI5
Other than above
Setting prohibited
Address
FF13H
Symbol
ADS3
6
0
7
0
5
0
4
0
3
ADS33
2
ADS32
1
ADS31
0
ADS30
After reset
00H
R/W
R/W