1. Disk Operations
Express5800/R320c-E4, R320c-M4 Maintenance Guide (Linux)
97
Chapter 2 Configuring and Upgrading the System
Command action
1 List RAID Arrays
2 List Internal Disks
3 Make Mirroring Arrays (RAID1)
4 Repair Mirroring Arrays (RAID1)
5 Delete Mirroring Arrays (RAID1)
6 Remove Disk Partitions (RAID1)
7 Make Striping Array (RAID1+0)
8 Delete Striping Array (RAID1+0)
c Configurations
q Quit
Command: 1 ------------------------------------------------------ (*1)
[List RAID Arrays]
Name Partition (Label) Status Member
===============================================================================
< Mirroring Array (RAID1) >
md0 /boot ( - ) SIMPLEX (1)sda1
md1 /var/crash ( - ) SIMPLEX (1)sda2
md2 swap ( - ) SIMPLEX (1)sda3
md3 / ( - ) SIMPLEX (1)sda5
-------------------------------------------------------------- (*2)
Command action
1 List RAID Arrays
2 List Internal Disks
3 Make Mirroring Arrays (RAID1)
4 Repair Mirroring Arrays (RAID1)
5 Delete Mirroring Arrays (RAID1)
6 Remove Disk Partitions (RAID1)
7 Make Striping Array (RAID1+0)
8 Delete Striping Array (RAID1+0)
c Configurations
q Quit
*1 Make sure the specified hard disk drive is removed from RAID.
*2 After making sure that the specified disk is properly isolated from redundant configuration (partition of the disk
specified as a member is not displayed), replace the disk.
After inserting a new disk, wait approximately 5 minutes until the system starts resynchronization. If the system
does not perform resynchronization automatically, recover RAID manually