156
-
9.
Check the following items for correct values:
–
Chassis Type, Chassis Part Number, Chassis Serial Number, and Chassis Characteristics
If finding any incorrect value, correct it from the keyboard. Position the cursor to the
target item to reverse, and press
Enter
. You can enter (correct) the value.
The default values for the server are shown below.
140Rd-4 (Rack)
140He (Tower)
ChassisType
17 (17h: Rack Mount Chassis)
07 (07h: Tower)
ChassisPartNumber 243-411567-001
243-411575-001
ChassisSerialNumber 01
05
ChassisCharacteristics 06
06
10.
Press
ESC
to return to the previous menu. Position the cursor to [Start to update] to
reverse, and press
Enter
. The window shown below appears.
Customize Product/Chassis Information
Updates the Product/Chassis Information.
Yes:[Enter] No:[ESC]
11.
Press
Enter
. The system starts writing to the non-volatile memory of the I/O board.
The message shown below is displayed during write operation.
Customize Product/Chassis Information
Updating now.
12.
The write operation is completed when the message shown below appears. Press
ESC
.
Customize Product/Chassis Information
Normal End.
OK:[Enter]
NOTE:
Without a backup data, the RMC data (remote
management data) must be restored in manual mode by the
remote management feature of the OS.
Summary of Contents for EXPRESS5800/140He
Page 1: ...Nec coF S e r v i c e G u i d e EXPRESS5800 140He EXPRESS5800 140Rd 4 ...
Page 2: ...This page is intentionally left blank ...
Page 4: ...This page is intentionally left blank ...
Page 144: ... 128 8 2 3 Processor and VRM Processor 1 Processor 2 Processor 4 Processor 3 ...
Page 153: ... 137 voltage drop and the system is restarted This is not an error ...
Page 161: ... 145 No Error message Action 8 The firmware is erased unsuccessfully ...
Page 163: ... 147 ...
Page 181: ... 165 12 3 Block Diagram ...
Page 182: ... 166 This page is intentionally left blank ...
Page 183: ... 167 This page is intentionally left blank ...
Page 184: ... 168 ...