132
-
On-screen message
Action
0B74
The error occurred during voltage
sensor reading
Replace the I/O board.
0B75
System Voltage out of the range
Check the system event log to identify the
voltage sensor which has detected the
out-of-range voltage.
0B78
The error occurred during fan sensor
Replace the I/O board.
0B7C
The error occurred during the
redundant power module confirmation
Replace the power supply unit.
0B7D
The normal operation can't be
guaranteed with use of only one PSU
Check the AC cord connection.
Replace the power supply unit.
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check
failed.
0B82
BMC Core hardware failed.
0B83
BMC IBF or OBF check failed.
Power off the system. Disconnect the power
cable and connect it again, cycle the power,
then restart the system.
Replace the I/O board.
0B8A
BMC SEL area full
Check the system event log, and then clear
it.
0B8B
BMC progress check timeout
0B8C
BMC command access faild
0B8D
Could not redirect the console - BMC
Busy
0B8E
Could not redirect the console - BMC
Error
0B8F
Could not redirect the console - BMC
Parameter Error
0B90 BMC
PlatformInformation
Area
Corrupted.
0B91
BMC Update firmware corrupted
0B92
Internal Use Area of BMC FRU
corrupted
0B93
BMC SDR Repository Empty.
Power off the system. Disconnect the power
cable and connect it again, cycle the power,
then restart the system.
Replace the I/O board.
0B94
IPMB signal lines do not respond.
0B95
BMC FRU device failure.
0B96
BMC SDR Repository Failure
0B97
BMC SEL device failure.
0B98
BMC RAM test error
0B99
BMC Fatal hardware error
0B9A
BMC not responding
0B9B
Private I2C bus not responding
0B9C BMC
internal
exception
0B9D BMC
A/D
timeout
0B9E SDR
repository
0B9F SEL
corrupt
Power off the system. Disconnect the power
cable and connect it again, cycle the power,
then restart the system.
Replace the I/O board.
0BB0
SMBIOS – SROM data read error
0BB1
SMBIOS – SROM data read error
Power off the system. Disconnect the power
cable and connect it again, cycle the power,
then restart the system.
Replace the I/O board.
Replace the relevant board.
Summary of Contents for EXPRESS5800/140He
Page 1: ...Nec coF S e r v i c e G u i d e EXPRESS5800 140He EXPRESS5800 140Rd 4 ...
Page 2: ...This page is intentionally left blank ...
Page 4: ...This page is intentionally left blank ...
Page 144: ... 128 8 2 3 Processor and VRM Processor 1 Processor 2 Processor 4 Processor 3 ...
Page 153: ... 137 voltage drop and the system is restarted This is not an error ...
Page 161: ... 145 No Error message Action 8 The firmware is erased unsuccessfully ...
Page 163: ... 147 ...
Page 181: ... 165 12 3 Block Diagram ...
Page 182: ... 166 This page is intentionally left blank ...
Page 183: ... 167 This page is intentionally left blank ...
Page 184: ... 168 ...