![NEC Express5800/120Lj User Manual Download Page 232](http://html.mh-extra.com/html/nec/express5800-120lj/express5800-120lj_user-manual_251189232.webp)
8-12 Troubleshooting
Error
code
Error message
Recommended Action
0B74
The error occurred during voltage sensor
reading.
0B75
System voltage out of the range.
Contact your service representative.
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core Hardware failure.
0B83
BMC 1BF or 0BF check failed.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
0B8A
BMC SEL area full.
Start SETUP and select [Server] - [Event Log
Configuration] - [Clear All Error Logs] and
press
Enter
to clear event logs.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
0B92
Internal Use Area of BMC FRU corrupted.
This is not a fatal error. Turn off the power
once and then on again to restart the server. If
the error cannot be corrected, contact your
service representative.
0B93
BMC SDR Repository empty.
Turn off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service representative.
0B94
IPMB signal lines do not respond.
This is not a fatal error. Turn off the power
once and then on again to restart the server. If
the error cannot be corrected, contact your
service representative.
0B95
BMC FRU device failure.
This is not a fatal error. Turn off the power
once and then on again to restart the server. If
the error cannot be corrected, contact your
service representative.
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error.
0B99
BMC Fatal hardware error.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
0B9A
BMC not responding.
Update the RMC firmware. If the error cannot
be corrected, contact your service
representative.
0B9B
Private I2C bus not responding.
0B9C
BMC internal exception.
0B9D
BMC A/D timeout error.
0B9E
SDR repository corrupt.
0B9F
SEL corrupt.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
Summary of Contents for Express5800/120Lj
Page 16: ...x This page is intentionally left blank ...
Page 36: ...2 8 General Description Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15 ...
Page 143: ...Configuring Your Server 4 75 3 Setting menu for VD 0 is displayed ...
Page 220: ...7 12 Maintenance This page is intentionally left blank ...
Page 352: ...9 94 Upgrading Your Server This page is intentionally left blank ...
Page 353: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Page 360: ...10 8 Internal Cabling Diagrams This page is intentionally left blank ...
Page 362: ...A 2 Specifications This page is intentionally left blank ...
Page 370: ...C 2 IRQ This page is intentionally left blank ...
Page 426: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 430: ...G 4 Product Configuration Record Table This page is intentionally left blank ...