![NEC Express5800/120Lj User Manual Download Page 100](http://html.mh-extra.com/html/nec/express5800-120lj/express5800-120lj_user-manual_251189100.webp)
4-32 Configuring Your Server
Reconstruction
The reconstruction feature is used to change configuration and/or RAID level of existing virtual
disk. The Reconstruction contains the following three features, however, the Internal RAID
Controller (equivalent to N8103-116) supports "Migration with addition" only.
IMPORTANT:
You can use WebBIOS for Reconstruction. Universal
RAID Utility does not support Reconstruction.
Removed physical drive
Unsupported.
Migration only
Unsupported.
Migration with addition
Use this feature to add HDDs to existing virtual disk. The execution patterns are as shown below (
α
:
Number of HDDs to be added).
Before execution
After execution
RAID
level
Number of
HDDs
RAID
level
Number of
HDDs
Description
RAID0
x
RAID0
x+
α
Capacity increased: equivalent to
α
HDDs
RAID0
1
RAID1
2
Capacity remains unchanged.
RAID0
x
RAID5
x+
α
Capacity increased: equivalent to
α
-1 HDDs
RAID0
x
RAID6
x+
α
(
α
=2 or more)
Capacity increased: equivalent to
α
-2 HDDs
RAID1
2
RAID0
2+
α
Capacity increased: equivalent to
α
+1 HDDs
RAID1
2
RAID5
2+
α
Capacity increased: equivalent to
α
HDDs
RAID1
2
RAID6
2+
α
Capacity increased: equivalent to
α
-1 HDDs
RAID5
x
RAID0
x+
α
Capacity increased: equivalent to
α
+1 HDDs
RAID5
x
RAID5
x+
α
Capacity increased: equivalent to
α
HDDs
RAID5
x
RAID6
x+
α
Capacity increased: equivalent to
α
-1 HDDs
RAID6
x
RAID0
x+
α
Capacity increased: equivalent to
α
+2 HDDs
RAID6
x
RAID5
x+
α
Capacity increased: equivalent to
α
+1 HDDs
RAID6
x
RAID6
x+
α
Capacity increased: equivalent to
α
HDDs
Summary of Contents for Express5800/120Lj
Page 16: ...x This page is intentionally left blank ...
Page 36: ...2 8 General Description Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15 ...
Page 143: ...Configuring Your Server 4 75 3 Setting menu for VD 0 is displayed ...
Page 220: ...7 12 Maintenance This page is intentionally left blank ...
Page 352: ...9 94 Upgrading Your Server This page is intentionally left blank ...
Page 353: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Page 360: ...10 8 Internal Cabling Diagrams This page is intentionally left blank ...
Page 362: ...A 2 Specifications This page is intentionally left blank ...
Page 370: ...C 2 IRQ This page is intentionally left blank ...
Page 426: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 430: ...G 4 Product Configuration Record Table This page is intentionally left blank ...