![background image](http://html1.mh-extra.com/html/nec/express-5800-120eh-n8100-series/express-5800-120eh-n8100-series_user-manual_4237405103.webp)
Configuring Your Server 4-39
Manual Rebuild
Replace hard disk drive
Run LSI Logic Software RAID Setup Utility
Execute rebuilding
Exit LSI Logic Software RAID Setup Utility
1.
Replace a hard disk drive and turn on the server.
2.
Run LSI Logic Software RAID Setup Utility.
3.
Select "Rebuild" from the TOP menu.
The "Rebuild – PHYSICAL DRIVES SELECTION MENU" screen appears.
4.
Move the cursor onto the hard disk drive displaying "FAIL," and then press
Space
to
select it.
Multiple hard disk drives can be selected (simultaneous rebuilding.)
5.
The "FAIL" indication for the hard disk drive selected starts blinking.
6.
When hard disk drive has been selected, press
F10
to start rebuilding.
7.
When confirmation screen for execution appears. Select "Yes".
The rebuild process starts.
When the progress bar in the "Rebuild Physical Drives in Progress" screen indicates 100%,
rebuilding is completed.
8.
Press
Esc
to return to the TOP menu and exit LSI Logic Software RAID Setup Utility.
Summary of Contents for Express 5800/120Eh N8100 SERIES
Page 16: ...x This page is intentionally left blank...
Page 32: ...2 4 General Description SATA Model 1 Additional slot 1 2 3 4 5 6 10 9 7 8 Additional slot 2 11...
Page 36: ...2 8 General Description Internal View SAS Model 1 2 4 5 1 6 7 8 3 2 3 1 5 2 10 9...
Page 52: ...2 24 General Description This page is intentionally left blank...
Page 112: ...4 48 Configuring Your Server This page is intentionally left blank...
Page 176: ...7 12 Maintenance This page is intentionally left blank...
Page 338: ...E 24 Installing Windows Server 2003 This page is intentionally left blank...
Page 342: ...F 4 Product Configuration Record Table This page is intentionally left blank...